V I I . O P E R A T I O N
Actuator Lighting Module (Not Shown)
Theactuatorlightingmoduleisalsolocatedonthepowerbase.Theactuatorlightingmoduleprovidesacontrolandpowerinterface betweenthepowermodule,thelights,and/orthepowerseatactuator.
Sleep Mode
Your Remote Plus controller has a sleep mode feature. Sleep mode is a
Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that are flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly flashing meter. When you get a trouble code, contact your authorized Pride provider.
FLASHING LIGHTS | DIAGNOSIS | SOLUTION |
|
|
|
10 | High Battery Voltage | Check batteries. |
|
|
|
9 | Solenoid Brake Fault | Check motor/brake wiring. |
|
|
|
8 | Possible Controller Fault | See authorized Pride provider. |
|
|
|
7 | Possible Joystick Fault | See authorized Pride provider. |
|
|
|
6 | Inhibit Active | Unplug charger. Check connections. |
|
|
|
5 | Right Motor Wiring Fault | Check right motor wiring. |
|
|
|
4 | Right Motor Disconnected | Check right motor wiring. |
|
|
|
3 | Left Motor Wiring Fault | Check left motor wiring. |
|
|
|
2 | Left Motor Disconnected | Check left motor wiring. |
|
|
|
1 | Low Battery Voltage | Check batteries/battery wiring. |
|
|
|
34 | www.pridemobility.com | Quantum Jazzy 1400 Series Rev D May 04 |