Pride Mobility Quantum 500 manual B a T T E R I E S a N D C H a R G I N G, Batteries and Charging

Page 28

V I . B A T T E R I E S A N D C H A R G I N G

BATTERIES AND CHARGING

The Quantum 500 uses two long-lasting, 12-volt, deep-cycle batteries. These batteries are sealed and maintenance free. Since they are sealed, there is no need to check the electrolyte (fluid) level. Deep-cycle batteries are designed to handle a longer and deeper discharge. Though they are similar in appearance to automotive batteries, they are not interchangeable. Automotive batteries are not designed to handle a long, deep discharge, and also are unsafe for use in power chairs.

WARNING! Battery posts, terminals, and related accessories contain lead and lead compounds. Wash hands after handling.

Charging the Batteries

The battery charger is essential in providing long life for your power chair batteries. It is designed to optimize your power chair’s performance by charging the batteries safely, quickly, and easily.

WARNING! You must recharge your power chair’s batteries with the supplied off-board battery charger. Do not use an automotive-type battery charger.

PROHIBITED! Removal of grounding prong can create electrical hazard. If necessary, properly install an approved 3-pronged adapter to an electrical outlet having 2-pronged plug access. Failure to heed could result in personal injury and/or property damage.

PROHIBITED! Never use an extension cord to plug in your battery charger. Plug the charger directly into a properly wired standard wall outlet.

Tochargethebatteriesusingtheoff-boardcharger:

1.Positionyourpowerchairnexttoastandardwalloutlet.

2.Becertainthecontrollerpoweristurnedoff.

3.Plugtheoff-boardchargerintotheoff-boardcharger/programmingsocketonthecontroller.SeeVII.“Operation.”

4.Plugtheoff-boardchargerintothewalloutlet.

NOTE: If it is a Pride off-board charger, then there are two lights in it. The red light indicates that power to the off-board charger is on. The green light indicates that the batteries are fully charged. If it is not a Pride off- board charger, then follow the instructions supplied by the manufacturer.

5. Whenthebatteriesarefullycharged,unplugtheoff-boardchargerfromthewalloutletandthenfromthecontroller.

Battery Break-in

To break in new batteries for maximum efficiency:

1.Fullyrechargeanynewbatterypriortoitsinitialuse.Thisbringsthebatteryuptoabout90%ofitspeakperformancelevel.

2.Operate your power chair throughout the house and yard. Move slowly at first, and don’t travel too far until you become accustomedtothecontrolsandbreakinthebatteries.

3.Givethebatteriesanotherfullchargeof8to14hoursandoperateyourpowerchairagain.Thebatterieswillnowperformatover 90%oftheirpotential.

4.Afterfourorfivechargingcycles,thebatterieswilltopoffat100%chargeandlastforanextendedperiod.

28

www.quantumrehab.com

Quantum 500

Image 28
Contents Page F E T Y G U I D E L I N E S N T E N T S PURCHASER’S Agreement N T R O D U C T I O NInformation Exchange Pride Owners Club My Quantum Rehab SpecialistProduct Safety Symbols S a F E T YS a F E T Y Pre-Ride Safety Check ModificationsTire Inflation Weight LimitationsIncline Information Cornering Information Braking InformationPublic Streets and Roadways Freewheel Mode Outdoor Driving SurfacesStationary Obstacles Steps, Curbs, etc Stairs and EscalatorsTransfers DoorsElevators Lift/Elevation ProductsInclement Weather Precautions Motor Vehicle TransportPositioning Belts Reaching and BendingAlcohol Electromagnetic and Radio Frequency Interference EMI/RFII . Y O U R P O W E R C H a I R QuantumQuantum 500 Specifications Quantum 500 Power Base Electrical ComponentsQuantum 500 Electrical Components Manual Freewheel Levers To engage or disengage the drive motorsInitial Assembly A S S E M B L YTo install the seat Seat InstallationController Installation O M F O R T a D J U S T M E N T S Seat Height and Seat Angle AdjustmentTo change the seat height Seatback Angle Adjustment To adjust the seatback angleTo adjust the recline angle Seat PositionArmrest Width Adjustment Armrest Angle Adjustment To change the armrest angleFoot Platform Depth To adjust the foot platform depth To change the armrest widthTo adjust the foot platform angle To clamp the quick release fastenerFoot Platform Angle Controller PositionTo adjust the SFR length To adjust the ELR angleTo adjust the ELR length To adjust the forward/back positionTo adjust the leg rest length Multi-Axis Foot PlateTo change leg rest length a To change foot plate position BTochargethebatteriesusingtheoff-boardcharger Battery Break-inB a T T E R I E S a N D C H a R G I N G Batteries and ChargingFrequently Asked Questions FAQs Howdoesthechargerwork? Can I use a different battery charger?How often must I charge the batteries? Daily UseWhy do my new batteries seem weak? How can I ensure maximum battery life?How should I store my power chair and its batteries? What about public transportation?I . O P E R a T I O N VSI Electronic ControllerVSI consists JoystickBattery Condition Meter KeypadOn/Off Key Red, yellow, and green lights lit Batteries chargedMotor Connectors Controller ConnectorBattery Connector Power Seat Actuator ConnectorVSI Error Codes Thermal RollbackCare and Maintenance Should your power chair come in contact with waterTemperature I I . C a R E a N D M a I N T E N a N C EDaily Checks Weekly ChecksTo check the brakes Monthly ChecksYearly Checks Cleaning Instructions Tire/Wheel ReplacementStorage Battery Replacement To replace the batteriesBattery Installation When to See Your Quantum Rehab Specialist for Service Corrective MaintenanceW a R R a N T Y Reconditioned Units Warranty Warranty ExclusionsService Checks and Warranty Service Exclusions also include components with damage caused byQuality Control Quantum Inspector