V I I I . C A R E A N D M A I N T E N A N C E

Yearly Checks

Take your power chair to your Quantum Rehab Specialist for yearly maintenance. This helps ensure that your power chair is functioning properly and helps prevent future complications.

Storage

Your power chair should be stored in a dry place, free from temperature extremes. When storing, disconnect the batteries from the power chair. See VI. “Batteries and Charging.”

WARNING! If you fail to store the unit properly, the frame can rust and the electronics can be damaged.

Cleaning Instructions

WARNING! Never hose off your power chair or place it in direct contact with water. Your power chair has a painted, ABS plastic body shroud that allows it to be easily wiped clean with a damp cloth.

WARNING! Never use any chemicals to clean a vinyl seat, as they may cause the seat to become slippery or dry out and crack. Use soapy water and dry the seat thoroughly.

Tire/Wheel Replacement

If you have pneumatic tires and you have a flat tire, you can replace the tube. If your chair is equipped with a solid tire insert, then you must replace the whole wheel assembly. Replacement tires, tubes, and wheel assemblies are readily available through your Quantum Rehab Specialist.

WARNING! To avoid possible injury, be sure that the controller’s power is turned off and the power chair is not in freewheel mode before performing this procedure.

WARNING! Completely deflate the tire before attempting repair.

Follow these easy steps for a quick and safe repair for both pneumatic and solid tires:

1.Turnoffthepowertothecontroller.

2.Setthepowerchairuponblocks.

3.Ifyouarechangingapneumatictire,completelydeflateit

beforeremovingthewheel.

4.Removethedrivewheelnutfromthewheelhub.

5.Pullthewheelofftheaxle.

6.Removethescrewsthatfastenthetworimhalvestogether. Seefigure25.

7.Removetheoldtubefromthepneumatictireandreplaceitwith anewtubeorreplacetheentireassemblyifitisasolidtire.

8.Screwtogetherthetworimhalves.

9.Slidethewheelbackontotheshaft.Makesurethatthekeyis intheaxleslot.

10.Reinstallthedrivewheelnutontothewheelhubandtighten.

11.Inflatethepneumatictireto35psi(2.4bar) ifequippedwith pneumatictires.

12.Removethepowerchairfromtheblocks.

SCREWS

TIRE

REAR RIM HALF

FRONT RIM HALF

NUT

Figure 25. Quantum 500 Drive Wheel

Quantum 500

www.quantumrehab.com

37

Image 37
Contents Page F E T Y G U I D E L I N E S N T E N T S PURCHASER’S Agreement N T R O D U C T I O NInformation Exchange My Quantum Rehab Specialist Pride Owners ClubS a F E T Y Product Safety SymbolsS a F E T Y Modifications Pre-Ride Safety CheckTire Inflation Weight LimitationsIncline Information Cornering Information Braking InformationPublic Streets and Roadways Outdoor Driving Surfaces Freewheel ModeStationary Obstacles Steps, Curbs, etc Stairs and EscalatorsDoors TransfersElevators Lift/Elevation ProductsMotor Vehicle Transport Inclement Weather PrecautionsPositioning Belts Reaching and BendingElectromagnetic and Radio Frequency Interference EMI/RFI AlcoholQuantum I . Y O U R P O W E R C H a I RQuantum 500 Specifications Electrical Components Quantum 500 Power BaseQuantum 500 Electrical Components To engage or disengage the drive motors Manual Freewheel LeversA S S E M B L Y Initial AssemblyTo install the seat Seat InstallationController Installation O M F O R T a D J U S T M E N T S Seat Height and Seat Angle AdjustmentTo change the seat height To adjust the seatback angle Seatback Angle AdjustmentTo adjust the recline angle Seat PositionArmrest Angle Adjustment To change the armrest angle Armrest Width AdjustmentFoot Platform Depth To adjust the foot platform depth To change the armrest widthTo clamp the quick release fastener To adjust the foot platform angleFoot Platform Angle Controller PositionTo adjust the ELR angle To adjust the SFR lengthTo adjust the ELR length To adjust the forward/back positionMulti-Axis Foot Plate To adjust the leg rest lengthTo change leg rest length a To change foot plate position BBattery Break-in Tochargethebatteriesusingtheoff-boardchargerB a T T E R I E S a N D C H a R G I N G Batteries and ChargingCan I use a different battery charger? Frequently Asked Questions FAQs Howdoesthechargerwork?How often must I charge the batteries? Daily UseHow can I ensure maximum battery life? Why do my new batteries seem weak?How should I store my power chair and its batteries? What about public transportation?VSI Electronic Controller I . O P E R a T I O NVSI consists JoystickKeypad Battery Condition MeterOn/Off Key Red, yellow, and green lights lit Batteries chargedController Connector Motor ConnectorsBattery Connector Power Seat Actuator ConnectorThermal Rollback VSI Error CodesShould your power chair come in contact with water Care and MaintenanceTemperature I I . C a R E a N D M a I N T E N a N C EWeekly Checks Daily ChecksTo check the brakes Monthly ChecksYearly Checks Cleaning Instructions Tire/Wheel ReplacementStorage To replace the batteries Battery ReplacementBattery Installation Corrective Maintenance When to See Your Quantum Rehab Specialist for ServiceW a R R a N T Y Warranty Exclusions Reconditioned Units WarrantyService Checks and Warranty Service Exclusions also include components with damage caused byInspector Quality Control Quantum