10 BATTERIES
4.Disconnect the wiring harness from the batteries by holding the connectors and pulling them in the following order (Detail “B” of FIGURE 10.3):
A.NEGATIVE
B.POSITIVE (+) RED battery cable from the POSITIVE (+) battery terminal on the right battery.
C.WHITE battery cable (Jumper) from the POSITIVE (+) battery terminal on the left battery and the NEGATIVE
5.Remove the tape securing the thermal switch to the side of the left battery.
6.Remove the batteries from battery box by lifting the batteries out.
Installing
1.Install the two new batteries into the battery box.
2.Secure the thermal switch to the side of the left battery using tape.
The thermal switch needs to be well secured and in direct contact with the side of the battery. Service tape is available as a service part and is the recommended solution. As an alternate, a heavy duty “duct” styled tape can be used. If “duct” styled tape is used, wrapping the tape completely around the battery with minimal overlap will provide the best adhesion.
3.Connect the wiring harness to the batteries in the following order (Detail “B” of FIGURE 10.3):
A.NEGATIVE
B.POSITIVE (+) RED battery cable to the POSITIVE (+) battery terminal on the right battery.
C.WHITE battery cable (Jumper) to the POSITIVE (+) battery terminal on the left battery and the NEGATIVE
4.Replace the top of the battery box and secure with the twelve mounting screws (Detail “A” of FIGURE 10.3). Securely tighten.
5.Reinstall the battery box on to the scooter frame. Refer to Removing/Installing the Battery Box on page 38.
6.Reinstall the seat. Refer to Removing/Installing the Seat on page 23.
Invacare® Lynx™ | 40 | Part No. 1143205 |