Omega Engineering #M3350/0101 manual Holding Pausing Recipe Execution

Page 63

CN8-SWUserÕs Guide

9.3.2 Holding (Pausing) Recipe Execution

To hold execution of a CN8-SW recipe:

1.While logged in as MULTI (or another user with View/Change Parameter privileges), select Ramp/Soak Hold. The Recipe Control window will open.

2.The window lists all the recipes being run under the direction of CN8-SW.

A recipe may appear on the list in the left pane more than once. This means that you started to run the recipe on different controllers (or sets of controllers) at different times. Each of these occurrences of a recipe on the list is referred to as an ÒinstanceÓ of the recipe.

To see on which controller(s) you are currently executing an instance of a recipe,

click on the name of the recipe. The controllers running the selected instance of the recipe that are not already on hold will be listed in the right pane.14

3.Select the instance of the recipe to be held.

4.Select the controllers to be held. (You can hold down the Shift key to select multiple controllers that are together on the list, or hold down the Control key to select multiple controllers that are scattered on the list.)

5.Click on Hold. Execution of the selected instance of the CN8-SW recipe will be paused for the selected controllers, and the window will close. On the CN8-SW main display, the PV of the ÒheldÓ controllers will alternate with the display of ÒHOLdÓ.

Execution of the selected instance of the recipe will be held for the selected controllers until you resume execution as described in 9.3.3, or stop (terminate) execution as described in 9.3.4.

14If all controllers on which you are running the selected recipe instance are already held, then no controllers will be listed in the right pane.

9-6

Image 63
Contents CN8-SW Table of Contents CN8-SWUserÕs Guide Changing Controller Mode and Using AutotuneViewing and Changing Controller Configuration Parameters Configuring and Running Ramp and Soak Recipes11-1 Table of ContentsCN8-SWUserÕs Guide Transforms a PC into an Operator Station FeaturesGraphical Interface Introduction Storing and Loading Configuration Parameter SetsAutomated Ramp and Soak Cycles LoggingControllers Local AlarmsHardware and Software Requirements 1 CN8-SW ComputerStep Task Section This Manual Overview of Setup TasksCN8-SWUserÕs Guide Step Task Section in this Manual Function Purpose Section Overview of CN8-SW MenusAvailability of Functions File MenuEdit Menu View MenuController Menu Alarms Options Menu Ramp/Soak MenuHelp Menu Menu Convention Used in This Manual General Instructions for Using CN8-SW WindowsCN8-SWUserÕs Guide Introduction Wiring the Network and Connecting the ComputerConnecting Controllers and the Computer to the Network Introduction2 RS-232 Interface 3 RS-485 Network Wiring the Network and Connecting the ComputerCN8-SWUserÕs Guide Installing the Software and Logging Installing the SoftwareTo install the software CN8-SWUserÕs Guide Starting the Software Installing the Software and LoggingTo log Logging In to CN8-SW Using the Default AccountTo change the password Changing the Password for the Default AccountSetting Up Operator Accounts Permissions AvailableTo see the permissions available to a user account To add an operator login account ProcedureEditing an Operator Account Deleting an Operator AccountLogging Out of the CN8-SW Application Establishing Communication with Controllers Communication Parameters Establishing Communication with Controllers Network AddressesTo configure the CN8-SW communication settings Configuring Communication Parameters for CN8-SW SystemEstablishing Communication with Controllers Recognizing Controllers with the CN8-SW Software Automatically Using the Find Controllers OptionTo use the automatic function If any controllers were not recognized Page To add a controller manually Manually Using the Controller MenuTo delete a controller Deleting a ControllerChanging Baud Rate after Communication Has Been Established Establishing Communication with Controllers Creating a New .MCS File Naming ControllersSaving the .MCS File Closing an .MCS FileOpening an Existing .MCS File CN8-SWUserÕs Guide Procedure Configuring Local AlarmsCN8-SWUserÕs Guide Viewing Process Values and Changing Setpoint Viewing PV and SP in the Main Window To view the real-time trend graph Viewing PV and SP in a GraphChanging the Setpoint Using the Setpoint Dialog Box To change a controllerÕs setpointSetpoint Configuring and Invoking the Single-Step Ramp Function CN8-SWUserÕs Guide To invoke the single step ramp function To change a controllerÕs mode Changing Controller Mode and Using AutotuneCN8-SWUserÕs Guide To access the parameter displays Viewing and Changing Controller Configuration ParametersAccessing Configuration Parameter Displays Using Configuration Parameter DisplaysCN8-SWUserÕs Guide Configuring and Running Ramp and Soak Recipes Creating a New Recipe Configuring CN8-SW Recipes Configuring and Running Ramp and Soak Recipes Editing an Existing Recipe Running CN8-SW Recipes Starting to Run a RecipeTo run a CN8-SW Ramp/Soak recipe To hold execution of a CN8-SW recipe Holding Pausing Recipe ExecutionTo resume execution of a ÒheldÓ recipe Resuming Recipe ExecutionTo stop execution of a CN8-SW recipe Stopping Recipe ExecutionConfiguring Controller Ramp and Soak Parameters CN8-SWUserÕs Guide Configuring and Running Ramp and Soak Recipes Running Controller Ramp and Soak Cycles Storing and Loading Controller Configurations Storing Configuration Storing and Loading Controller Configurations Loading Configuration Storing and Loading Controller Configurations 10-6 To turn on the logging function Turning On the Logging FunctionViewing and Printing Log Files Turning Off the Logging FunctionTo turn off the logging function Index 12-2