Scott 4.5, 3, 2.2 manual

Page 15

2.Evacuation

a)To send an evacuation message to all logged-in respirator us- ers, the Base Station operator must press and hold the “EVAC” button on the Base Station and then choose “ALL-CALL” from the menu on the display. The “EVAC message will be sent to all logged-in respirator users.

b)To send an evacuation message to only selected respirator users, the Base Station operator uses the scroll buttons to move up and down the list of logged-in respirator users and presses the “EVAC” button when the selected users are highlighted in the display.

c)The respirator users who receive the “EVAC” message must press the RESET button on the Control Console to acknowl- edge the message.

d)The Base Station listing of logged-in users will display “CONF” with each respirator user who has responded to the “EVAC” message.

3.Air Supply Monitoring

a)When the air supply cylinder reaches one-quarter of full pres- sure, the alert sound will occur and the Control Console will display “LOW AIR”. A low air signal will be sent to the Base Station within ten seconds. This end of service time indicator (EOSTI) alarm cannot be silenced by the user until the user leaves the hazardous area and shuts down the respirator.

b)The Base Station operator must press “ACK” on the Base Sta- tion to acknowledge the user’s low air signal.

15

Image 15
Contents Sems Description Base Station Sensor ModulePage Detecting and Avoiding Radio Frequency Interference Keep Radio Antennas AT Least SIX 6 Inches from These AreasRFI Warning Areas Programming FCC NoticeRadio Frequency Interference RFI Intrinsically Safe ListingBasic Functions of the Sems Equipment Portable Unit Operation of the Sems PDA Distress AlarmFull Alarm PRE AlarmTurning OFF the Sems PDA Distress Alarm Manual AlarmBattery Test Other Operational Features END of Service Time IndicatorUSE of the Sems PDA Portable Unit Evacuation Base Station USE of the Sems Base StationPage Event LOG Screen Event LOGSample Event LOG Regular Operational Inspection Regular Operational Inspection On Next Inspection of Sems PDA Distress AlarmInspection of Sems PDA Portable Unit Control Console Battery Replacement Sems PDA Distress Alarm Portable UnitBattery Cover Battery Compartment and Cover Seal Battery Replacement on NextCheck Your Work Control Console Battery Battery Orientation AS Shown Battery Compartments on Base StationMaintenance Does When the Sems PDA IT Indicates That Distress Alarm isSound Levels Performance SpecificationsRev a 6/03