Scott 2.2, 4.5, 3 Keep Radio Antennas AT Least, SIX 6 Inches from These Areas, RFI Warning Areas

Page 5

If the SEMS PDA distress alarm is affected by RFI when the respirator air supply is turned off or the cylinder is empty, the distress alarm could be turned off during use. If this occurs, depress the RED Manual Alarm Button and hold at least two seconds to activate the alarm.

IF THE SYMPTOMS OF RFI OCCUR, THE RESPIRATOR USER MUST CHECK THE SEMS PDA DISTRESS ALARM TO VERIFY THAT IT IS FUNCTIONING PROPERLY. IF THE GREEN LIGHT ON THE CONTROL CONSOLE DOES NOT RESUME FLASHING IN THE NORMAL MANNER AFTER EXPERIENCING THE SYMPTOMS OF RFI, OR IF THE UNIT CONTINUES TO MALFUNCTION IN ANY OTHER WAY, PROCEED TO A SAFE AREA, REMOVE THE RESPI- RATOR FROM SERVICE AND TAG FOR REPAIR BY AUTHORIZED PERSONNEL.

Minimize or eliminate the effects of RFI by protecting the SEMS PDA with the following steps:

Maintain a safe distance from a base station transmitting antenna or a truck mounted radio antenna.

Keep the antennas of hand held radios at least six (6) inches away from the CONTROL CONSOLE or the SENSOR MODULE (See FIGURE 2).

KEEP RADIO ANTENNAS AT LEAST

CONTROL

SIX (6) INCHES FROM THESE AREAS

CONSOLE

 

SENSOR

 

MODULE

WARNING

 

 

BE AWARE OF THE POTENTIAL EFFECT OF

 

RADIO TRANSMISSIONS FROM BASE STATION

 

OR TRUCK MOUNT RADIOS WHEN USING A

 

RESPIRATOR WITH THE SEMS PDA DISTRESS

 

ALARM. Close proximity of RADIO EQUIPMENT

 

to the SEMS PDA DISTRESS ALARM during ra-

 

dio transmission may cause the unit to MAL-

 

FUNCTION. FAILURE TO RECOGNIZE A MAL-

 

FUNCTION OF THE SEMS PDA DISTRESS

 

ALARM AND TAKE THE PROPER CORRECTIVE

 

ACTION MAY RESULT A NONWORKING DIS-

 

TRESS ALARM WHICH WILL NOT SOUND IF THE

 

USER STOPS MOVING AND LEAD TO SERIOUS

 

INJURY OR DEATH.

FIGURE 2

RFI WARNING AREAS

5

Image 5
Contents Sems Description Base Station Sensor ModulePage Detecting and Avoiding Radio Frequency Interference RFI Warning Areas Keep Radio Antennas AT LeastSIX 6 Inches from These Areas Radio Frequency Interference RFI FCC NoticeIntrinsically Safe Listing ProgrammingBasic Functions of the Sems Equipment Portable Unit Operation of the Sems PDA Distress AlarmFull Alarm PRE AlarmTurning OFF the Sems PDA Distress Alarm Manual AlarmBattery Test Other Operational Features END of Service Time IndicatorUSE of the Sems PDA Portable Unit Evacuation Base Station USE of the Sems Base StationPage Event LOG Screen Event LOGSample Event LOG Regular Operational Inspection Regular Operational Inspection On Next Inspection of Sems PDA Distress AlarmInspection of Sems PDA Portable Unit Control Console Battery Cover Battery ReplacementSems PDA Distress Alarm Portable Unit Check Your Work Battery Compartment and Cover SealBattery Replacement on Next Control Console Battery Maintenance Battery Orientation AS ShownBattery Compartments on Base Station Does When the Sems PDA IT Indicates That Distress Alarm isSound Levels Performance SpecificationsRev a 6/03