PERFORMANCE SPECIFICATIONS

Sound Levels:

 

Pre-Alarm

70 to 105 dBA incrementally at left ear

Full-Alarm

95 to 100 dBA @ 9.9 Ft (3m)

Frequency Range

1.5 KHz to 4 KHz

Battery Life (fresh battery)

 

Alkaline Battery:

 

Automatic (green flashing light, no sound)

Approx. 60 hours

Full Alarm (red flashing light, 95 dBA sound)

Approx. 8 hours

Lithium Battery:

 

Automatic (green flashing light, no sound)

> 120 hours

Full alarm (red flashing light, 95 dBA sound)

......... 8-16 hours

Compliance

The Scott SEMS PDA distress alarm is a NIOSH approved ac- cessory for use on only the following Scott AIR-PAK and AIR-PAK FIFTY respirators:

(NIOSH approval numbers have been included for identification):

Scott 2.2 Air-Pak (30 min.)

TC-13F-80

Scott 3.0 Air-Pak (30 min.)

TC-13F-366

Scott 4.5 Air-Pak (30 min.)

TC-13F-76

Scott 4.5 Air-Pak (45 min.)

TC-13F-212

Scott 4.5 Air-Pak (60 min.)

TC-13F-96

NOTE

DO NOT USE A FIBERGLASS WRAPPED ONE HOUR CYLIN- DER ON A MODEL 4.5 AIR PAK EQUIPPED WITH A SEMS PDA DISTRESS ALARM AS THE WEIGHT WILL EXCEED THE 35 LBS APPROVAL LIMIT FOR SCBA’s ESTABLISHED BY NIOSH.

Report any operational malfunctions to the certification agency Safety Equipment Institute (SEI), 1307 Dolley Madison Blvd. Suite 3A, McLean, VA 22101, (703) 442-5732, FAX (703) 442-5756.

27

Image 27
Contents Sems Description Base Station Sensor ModulePage Detecting and Avoiding Radio Frequency Interference Keep Radio Antennas AT Least SIX 6 Inches from These AreasRFI Warning Areas Programming FCC NoticeRadio Frequency Interference RFI Intrinsically Safe ListingBasic Functions of the Sems Equipment Portable Unit Operation of the Sems PDA Distress AlarmFull Alarm PRE AlarmTurning OFF the Sems PDA Distress Alarm Manual AlarmBattery Test Other Operational Features END of Service Time IndicatorUSE of the Sems PDA Portable Unit Evacuation Base Station USE of the Sems Base StationPage Event LOG Screen Event LOGSample Event LOG Regular Operational Inspection Regular Operational Inspection On Next Inspection of Sems PDA Distress AlarmInspection of Sems PDA Portable Unit Control Console Battery Replacement Sems PDA Distress Alarm Portable UnitBattery Cover Battery Compartment and Cover Seal Battery Replacement on NextCheck Your Work Control Console Battery Battery Orientation AS Shown Battery Compartments on Base StationMaintenance Does When the Sems PDA IT Indicates That Distress Alarm isSound Levels Performance SpecificationsRev a 6/03