WARNING
READ AND UNDERSTAND THE COMPLETE INSTRUCTION MANUAL BEFORE USING A RES- PIRATOR WITH A SEMS PDA DISTRESS ALARM INSTALLED.
QUICK REFERENCE GUIDE TO USE OF THE SEMS PDA DISTRESS ALARM:
| WHEN YOU WANT TO: |
| YOU DO: | THE SEMS PDA | |
|
|
|
|
| DISTRESS ALARM |
|
|
|
|
| DOES: |
|
|
|
|
|
|
| Turn it on. |
| Open cylinder valve | 3 quick audible chirps, | |
|
|
| (cylinder must have air | green flashing light on | |
|
|
| in it). |
| control console. |
|
|
|
|
|
|
| Reset |
| Move so that the respirator | Red flashing light changes | |
|
|
| moves or press reset | to green, ascending/de- | |
|
|
| button once. |
| scending tone stops (3 |
|
|
|
|
| quick audible chirps if |
|
|
|
|
| button was pressed). |
|
|
|
|
|
|
| Reset full alarm |
| Press reset button on | Loud 3 tone chirp stops, | |
|
|
| control console twice | 3 quick chirps, then red | |
|
|
| (push, release, push again). | flashing light changes to | |
|
|
|
|
| green flashing light. |
| Turn it off (finished |
| Close cylinder valve, open | The flashing light goes out | |
|
| regulator purge valve letting | |||
| with use) |
| and display will say OFF. | ||
|
| out all the trapped air, close | |||
|
|
| Unit will sound a two tone | ||
|
|
| regulator purge valve, press | ||
|
|
| chirp at turn off. | ||
|
|
| reset button twice after | ||
|
|
|
| ||
|
|
| flashing green light se- |
| |
|
|
| quence. |
|
|
|
|
|
|
|
|
| Turn on the |
| Press alarm button on | Goes into full alarm, loud 3 | |
| manual alarm. |
| control console (works | tone chirps from sensor | |
|
|
| whether the SEMS PDA | module and bright red | |
|
|
| distress alarm is on or off). | flashing light from control | |
|
|
|
|
| console. |
|
|
|
|
| |
|
|
|
| ||
| WHEN THE SEMS PDA | IT INDICATES THAT: | |||
| DISTRESS ALARM IS: | ||||
|
|
| |||
|
|
|
|
| |
| Quiet. No lights or sound |
| The SEMS PDA distress alarm is off or the | ||
|
| batteries are used up or removed. | |||
|
|
|
| ||
|
|
|
|
| |
|
|
|
| The SEMS PDA distress alarm is on, in | |
| Flashing the green light |
| automatic mode, and monitoring your | ||
|
|
|
| motion. |
|
|
|
|
|
| |
| Flashing the red light and sounding an | You have not moved in the last 20 sec- | |||
| onds, SEMS PDA distress alarm will go | ||||
| ascending/descending tone. |
| |||
|
| into full alarm in 12 seconds or less if you | |||
|
|
|
| ||
|
|
|
| do not move. |
|
|
|
|
|
| |
| Flashing the red light and sounding a | Full alarm: You have not moved in the last | |||
| 30 seconds or more or you pushed the | ||||
| loud continuous 3 tone chirp |
| |||
|
| manual alarm button and held at least two | |||
|
|
|
| ||
|
|
|
| seconds. |
|
| Chirping once every 2 seconds with no | The backframe batteries are low. You must | |||
| light flashing |
| replace all batteries before using the SEMS | ||
|
|
|
| PDA distress alarm again (it will work in | |
|
|
|
| low battery condition long enough to let | |
|
|
|
| you finish the cylinder of air you are on). |