Scott 4.5, 3, 2.2 manual

Page 3

The SEMS PDA distress alarm warns the user when the air supply cylinder has reached 50% of its full capacity and also functions as an electronic end of service time indicator for the respirator by sounding an alarm when the air supply cylinder has been depleted to 25% of its full capacity. The Control Console digital display shows the approxi- mate cylinder pressure. Details of the end of service time indicator operation are also discussed in the Operation and Maintenance in- structions provided with the respirator.

The SEMS PDR Base Station is a compact battery operated device that can be tripod mounted or carried by a strap. A digital display provides information about status of the respirator users who are logged onto the Base Station. Simple dedicated function buttons control the transmission and receipt of signals with the respirator users. The Base Station can be easily interfaced with a computer for programming and advanced applications.

When a respirator user opens the cylinder valve and begins use of an AIR-PAK SCBA equipped with the SEMS PDA, the Portable Unit will automatically begin to operate. If the SEMS PDR Base Station is present at time of entry, the SEMS PDA must log-in with the Base Station before entry into the hazardous area. Contact between the SEMS PDA Portable Unit and the Base Station will continue until the respirator user terminates use of the SCBA.

Each installation of SEMS equipment operates as a distinct set of Portable Units and Base Station that transmit and receive on a single frequency. If another installation of SEMS equipment is used in the same area, the operation of each group will remain discreet and separate between Portable Units and Base Stations. The SEMS equipment operates between 453.0375 and 465.6375 MHz on radio channels defined in FCC Title 47 (Telecommunications) Part 90 sec- tion 20, Limitation (27) and requirement Part 90.238. Programming of the Portable Units and Base Station is essential and must be performed prior to training and use. See SEMS Programming Guide, SCOTT P/N 89506-01 for complete details of programming the SEMS equipment.

The installation of the SCOTT SEMS PDA distress alarm is approved by the National Institute of Occupational Safety and Health (NIOSH) on all models of SCOTT AIR-PAK 2.2 / 3.0 / 4.5 / Fifty SCBA.

The SCOTT SEMS PDA distress alarm Portable Unit, when added to a SCOTT Air-Pak respirator, as shown in FIGURE XX, consists of a Sensor Module with battery compartment mounted to the bottom of the respirator backframe, a pressure gauge with transducer, and a Control Console mounted on the wearer’s right shoulder strap at the pressure gauge location. The SEMS PDA Portable Unit requires three

(3)nine volt batteries to operate: two in the Sensor Module on the backframe and one in the Control Console.

Installation of the SCOTT SEMS PDA distress alarm requires some disassembly of the respirator and should only be performed by an authorized service center. Contact SCOTT HEALTH AND SAFETY, Monroe, NC at 1-800-247-7257 for details.

WARNING

NO PERSONAL ALERT SAFETY SYSTEM, RES- PIRATOR OR COMBINATION OF PERSONAL ALERT SAFETY SYSTEM AND RESPIRATOR, BY THEMSELVES, CAN PROVIDE COMPLETE PROTECTION IN FIRE SITUATIONS. HOWEVER, USING AN ALARM AND A RESPIRATOR IN ACCORDANCE WITH THE REQUIREMENTS OF AN ORGANIZED RESPIRATORY PROTEC- TION PROGRAM IS ONE OF THE MANY SAFETY PRECAUTIONS WHICH SHOULD BE TAKEN TO AVOID PERSONAL INJURY OR DEATH.

3

Image 3
Contents Sems Description Base Station Sensor ModulePage Detecting and Avoiding Radio Frequency Interference Keep Radio Antennas AT Least SIX 6 Inches from These AreasRFI Warning Areas Programming FCC NoticeRadio Frequency Interference RFI Intrinsically Safe ListingBasic Functions of the Sems Equipment Portable Unit Operation of the Sems PDA Distress AlarmFull Alarm PRE AlarmTurning OFF the Sems PDA Distress Alarm Manual AlarmBattery Test Other Operational Features END of Service Time IndicatorUSE of the Sems PDA Portable Unit Evacuation Base Station USE of the Sems Base StationPage Event LOG Screen Event LOGSample Event LOG Regular Operational Inspection Regular Operational Inspection On Next Inspection of Sems PDA Distress AlarmInspection of Sems PDA Portable Unit Control Console Battery Replacement Sems PDA Distress Alarm Portable UnitBattery Cover Battery Compartment and Cover Seal Battery Replacement on NextCheck Your Work Control Console Battery Battery Orientation AS Shown Battery Compartments on Base StationMaintenance Does When the Sems PDA IT Indicates That Distress Alarm isSound Levels Performance SpecificationsRev a 6/03