Toshiba SL-9000N-FFR-US, SL-9000N-FFR-QR, SL-9000N-FFR-CA, SL-9000-FFR-QR, EO1-31001 Safety Summary

Page 3

Safety Summary

Safety Summary

Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment.

Do not attempt to effect repairs or modifications to this equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, unplug the machine, then contact your authorized TOSHIBA TEC representative for assistance.

Meanings of Each Symbol

This symbol indicates warning items (including cautions). Specific warning contents are drawn inside the symbol. (The symbol on the left indicates a general caution.)

This symbol indicates prohibited actions (prohibited items). Specific prohibited contents are drawn inside or near the symbol. (The symbol on the left indicates “no disassembling”.)

This symbol indicates actions which must be performed. Specific instructions are drawn inside or near the symbol.

(The symbol on the left indicates “disconnect the power cord plug from the outlet”.)

 

 

This indicates that there is the risk of death or serious injury if the

WARNING machines are improperly handled contrary to this indication.

Any other than the

 

Do not use voltages other than the

Prohibited

 

Do not plug in or unplug the power

specified AC voltage

 

 

voltage (AC) specified on the rating

cord plug with wet hands as this may

is prohibited.

 

 

plate, as this may cause fire or

 

cause electric shock.

 

electric shock.

 

 

 

Prohibited

 

If the machines share the same

Prohibited

 

 

Do not place metal objects or

 

 

 

 

outlet with any other electrical

water-filled containers such as flower

 

 

 

appliances which consume large

 

vases, flower pots or mugs, etc. on

 

amounts of power, the voltage will

 

top of the machines. If metal objects

 

fluctuate widely each time these

 

or spilled liquid enter the machines,

 

appliances operate. Be sure to

 

this may cause fire or electric

 

provide an exclusive outlet for the

 

shock.

 

machine as this may cause the

 

 

 

 

 

machines to malfunction.

 

 

 

 

 

 

 

 

 

 

 

Prohibited

 

Do not insert or drop metal,

Prohibited

 

 

Do not scratch, damage or modify

 

 

 

 

 

 

flammable or other foreign objects into

the power cords. Also, do not place

 

 

 

the machines through the ventilation

 

heavy objects on, pull on, or exces-

 

slits, as this may cause fire or electric

 

sively bend the cords, as this may

 

shock.

 

cause fire or electrical shock.

Disconnect

 

If the machines are dropped or their

Disconnect

 

Continued use of the machines in an

 

 

the plug.

cabinets damaged, first turn off the

the plug.

abnormal condition such as when the

 

power switches and disconnect the

 

machines are producing smoke or

 

power cord plugs from the outlet, and

 

strange smells may cause fire or elec-

 

then contact your authorized

 

tric shock. In these cases, immedi-

 

TOSHIBA TEC representative for

 

ately turn off the power switches and

 

assistance. Continued use of the

 

disconnect the power cord plugs from

 

 

the outlet. Then, contact your author-

 

machine in that condition may cause

 

 

 

ized TOSHIBA TEC representative for

 

fire or electric shock.

 

 

 

assistance.

 

 

 

 

(i)

Image 3
Contents SL-9000/9000N-FFR-US/CA/QR Page Safety Summary Precautions Table of Contents 14.2 13.113.2 14.1Introduction Applicable Model AccessoriesScale SpecificationTmcc OptionLON STLAN-2PLevel Gauge Label Guide Printer Cover Main Power SwitchAdjustable Legs Meat Platter Power Cord AppearanceDisplay US TypeCA/QR Type KEY Layout Programming KeyboardProgramming Keyboard Function Space SendProg Operation Keyboard and Speed Keyboard Operation Keyboard FunctionPLU Void PRTFor DT/TMZero Self Service KeyboardKEY Layout Speed KEY SET Procedure Before OperationInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation PowerTmcc CMT-port communicarion Clerk Label Registration modeXNOT Available 1/4LB KEY 100g, kg KEY LB/kg KEYHow to access to Programming Menu Programming ProceduresTitle and Contents of Programming Menu TEC Store How to enter charactersMenu PLU Data EditSet tare limit PLU Data SettingAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Set the Daily Value Table Daily Value Max digits Contents of Daily valueMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort Menu Item No Verifies PLU data stored in the scale PLU Verifying LabelAddress and Commercial Message Setting Message construction Message display time Combination MessageThank YOU ANK YOU Call AGA Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Thank YOU CallGrade Line Special InformationVendor Number Speed KEY SettingSetting Department/Vendor Number Department NumberBy pressing Key Print FormatFormat No Label Format Number TableDATE/TIME Setting Menu Item NoCMT Operations PL-3 Operation Error code during PL-3 operationTransmission Item List Item #CMT IN-LINE/LOCAL Transmission Delay Time TableLON System Initial #0 #19, SL-9000N only Cancel Retry ContinueData Transmission Price Address SL-9000N only② By Count Format Default Bar Code FormatBAR Code Format ① Weigh or Fix Price FormatPLU # UPC # PC/D Flag PLU # UPC # PC/D Price WeightAdditional 234 235 Additional 7,8 238 Additional 9,10 239 Title No Format Additional 221Additional 231 232 Additional 233Transferring Logo Data SL-9000N onlyVerify SL-9000=CMT Error message during data transmission Idiom SettingVendor Setting Free Format Setting Key functionsEnter SP-INFO/NET WT Logo Frequent Shopper Print coordinate How to access Report menu Programmed Data Verification ReportsMenu Set the zone PLU #. Ex. PLU #100 ~108 R S X Z Password SecuritySetting Password and Protect Menu R S× ー × Calling Menu by Entering Password How to access REG., M.DOWN, or Rewrap menu Operating ProceduresWeighing Operation Menu REG., M.DOWN, or Rewrap Mode WeighFIX Price Operation for US Type only By Count Operation For To check the remaining number, clear the PLU and press Key Print Count OperationExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # PLU Issuing Labels with NET Weight Statement for US Type onlySample label 14-10 TARE/SAVE Function Procedures Calling and Printing Grade Lines Logo Calling and Printing LogosSelecting Print Item Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Key Label Issue Stop or CancelTotals Overflow error occurs when Key is pressed to issueDpt # Visual Commodity LibraryFloating Vendor Subtotal Price deletionTotal Operation How to access Read or Reset menuEx. Report Menu Hourly Total ReportGrand Total Report PLU Total ReportFor Enter PLU Total Vendor Total ReportProgramming Mode Error Message TableReport and Reset Mode Label lssue ModeLON System Mode Cleaning the Print Head Before You Call for Service Troubleshooting