Toshiba EO1-31001GE, SL-9000N-FFR-QR, SL-9000N-FFR-CA Transmission Item List, Item #, Cmt

Page 47

11. PROGRAMMING PROCEDURES

11.13 CMT/PL-3

Table 4: Transmission Item List

ITEM #

Title on the Display

 

Contents of Transmission

CMT

PL-3

2

VERIFY PLU & ING. = CMT 2

COMPARE PLU & ING. IN OLD FORMAT

3

READ PLU & ING. FM CMT 3

READ PLU & ING. IN OLD FORMAT

 

 

 

 

 

 

4

WRITE PLU TO CMT

4

SAVE PLU IN NEW FORMAT

5

VERIFY PLU = CMT

5

COMPARE PLU IN NEW FORMAT

 

 

 

 

 

 

6

READ PLU FROM CMT

6

READ PLU IN NEW FORMAT

7

WRITE ING. TO CMT

7

SAVE ING. IN NEW FORMAT

×

 

 

 

 

 

 

8

VERIFY ING. = CMT

8

COMPARE ING. IN NEW FORMAT

×

9

READ ING. FROM CMT

9

READ ING. IN NEW FORMAT

×

 

 

 

 

 

 

10

WRITE NUTRI. TO CMT

10

SAVE NUTRITION IN NEW FORMAT

11

VERIFY NUTRI. = CMT

11

COMPARE NUTRITION IN NEW FORMAT

 

 

 

 

 

 

12

READ NUTRI. FM CMT

12

READ NUTRITION IN NEW FORMAT

13

WRITE SPEED KEY

13

SAVE SPEED KEY IN NEW FORMAT

 

 

 

 

 

 

14

VERIFY SPEED KEY

14

COMPARE SPEED KEY IN NEW FORMAT

15

READ SPEED KEY

15

READ SPEED KEY IN NEW FORMAT

 

 

 

 

 

 

: operable, ×: inoperable

NOTE: When the PL-3 is connected, more than one FDK may be required depending on the amount of ING. data.

Be careful of the following when changing a FDK.

a:During the write operation, replace with a formatted FDK.

b:Verify and read data in same order as the write.

To cancel to change a FDK, press the CLEAR key.

11-22

Image 47
Contents SL-9000/9000N-FFR-US/CA/QR Page Safety Summary Precautions Table of Contents 14.2 13.113.2 14.1Introduction Applicable Model AccessoriesScale SpecificationTmcc OptionLON STLAN-2PLevel Gauge Label Guide Printer Cover Main Power SwitchAdjustable Legs Meat Platter Power Cord AppearanceCA/QR Type DisplayUS Type Programming Keyboard Function KEY LayoutProgramming Keyboard Prog SpaceSend PLU Operation Keyboard and Speed KeyboardOperation Keyboard Function Void PRTFor DT/TMZero Self Service KeyboardKEY Layout Speed KEY SET Procedure Before OperationInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation PowerTmcc CMT-port communicarion Clerk Label Registration modeXNOT Available 1/4LB KEY 100g, kg KEY LB/kg KEYHow to access to Programming Menu Programming ProceduresTitle and Contents of Programming Menu TEC Store How to enter charactersMenu PLU Data EditSet tare limit PLU Data SettingAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Set the Daily Value Table Daily Value Max digits Contents of Daily valueMemory file sort Memory file is sorted when a memory full error occursDeleting Nutrition Data Menu Item No Verifies PLU data stored in the scale PLU Verifying LabelAddress and Commercial Message Setting Message construction Message display time Combination MessageThank YOU ANK YOU Call AGA Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Thank YOU CallGrade Line Special InformationVendor Number Speed KEY SettingSetting Department/Vendor Number Department NumberBy pressing Key Print FormatFormat No Label Format Number TableCMT Operations DATE/TIME SettingMenu Item No PL-3 Operation Error code during PL-3 operationCMT Transmission Item ListItem # IN-LINE/LOCAL Transmission Delay Time TableLON System Initial #0 #19, SL-9000N only Cancel Retry ContinueData Transmission Price Address SL-9000N only② By Count Format Default Bar Code FormatBAR Code Format ① Weigh or Fix Price FormatPLU # UPC # PC/D Flag PLU # UPC # PC/D Price WeightAdditional 234 235 Additional 7,8 238 Additional 9,10 239 Title No Format Additional 221Additional 231 232 Additional 233Verify SL-9000=CMT Transferring Logo DataSL-9000N only Error message during data transmission Idiom SettingVendor Setting Enter Free Format SettingKey functions SP-INFO/NET WT Logo Frequent Shopper Print coordinate Menu How to access Report menuProgrammed Data Verification Reports Set the zone PLU #. Ex. PLU #100 ~108 R S X Z Password SecuritySetting Password and Protect Menu R S× ー × Calling Menu by Entering Password How to access REG., M.DOWN, or Rewrap menu Operating ProceduresWeighing Operation Menu REG., M.DOWN, or Rewrap Mode WeighFIX Price Operation for US Type only By Count Operation For To check the remaining number, clear the PLU and press Key Print Count OperationExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # PLU Issuing Labels with NET Weight Statement for US Type onlySample label 14-10 TARE/SAVE Function Procedures Calling and Printing Grade Lines Logo Calling and Printing LogosSelecting Print Item Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Key Label Issue Stop or CancelTotals Overflow error occurs when Key is pressed to issueDpt # Visual Commodity LibraryFloating Vendor Subtotal Price deletionTotal Operation How to access Read or Reset menuEx. Report Menu Hourly Total ReportGrand Total Report PLU Total ReportFor Enter PLU Total Vendor Total ReportProgramming Mode Error Message TableReport and Reset Mode Label lssue ModeLON System Mode Cleaning the Print Head Before You Call for Service Troubleshooting