Toshiba EO1-31001GE owner manual Combination Message, Message construction Message display time

Page 39

11. PROGRAMMING PROCEDURES

11.7 COMBINATION MESSAGE

11.7COMBINATION MESSAGE

Menu Page: 1

Item No.: 6

You can combine some messages set in Section 11.6 together and create a maximum of 24 different combination messages.

Message construction

 

 

 

 

 

 

 

 

 

 

 

 

 

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n

n

n

n

n

n

n

n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message display time:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message display time ranges from 00 to 99 (seconds). When

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00is entered, no message will be displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3rd message:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01 to 08:

represents messeages No. 1 to 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 to 23:

represents logo No. 01 to 13

2nd message:

01 to 08: represents message No. 1 to 8

90 to 93: represents display methods 90: Flashing

91: Curtaining

92: Scrolling up

93: Scrolling down

1st message:

01 to 08: represents message No. 1 to 8

NOTE: When the fixed message is selected, set “00” as the 1st and 2nd messages. Otherwise, set “00” as the 1st message. When the Flashing, Curtaing, Scrolling up or Scrolling down is selected, set “00” as the 1st message.

<MENU>

Page 1

 

Enter the message

6

numbers to be included

 

in the group.

Enter the time to display the group of messages. (199 sec.)

ENTER

Enter the message No. and the display time.

PROG

ESC.

<MENU>

Page 1

Message displaying time 00 to 99 (seconds). When 00is

Mainentered, no message will be displayed. <MENU>

NOTE: The combination No. is selected as follows by ENTER

combi. 1 combi. 2 combi. 8

key.

11-14

Image 39
Contents SL-9000/9000N-FFR-US/CA/QR Page Safety Summary Precautions Table of Contents 14.2 13.113.2 14.1Introduction Applicable Model AccessoriesScale SpecificationTmcc OptionLON STLAN-2PLevel Gauge Label Guide Printer Cover Main Power SwitchAdjustable Legs Meat Platter Power Cord AppearanceDisplay US TypeCA/QR Type KEY Layout Programming KeyboardProgramming Keyboard Function Space SendProg Operation Keyboard and Speed Keyboard Operation Keyboard FunctionPLU Void PRTFor DT/TMZero Self Service KeyboardKEY Layout Speed KEY SET Procedure Before OperationInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation PowerTmcc CMT-port communicarion Clerk Label Registration modeXNOT Available 1/4LB KEY 100g, kg KEY LB/kg KEYHow to access to Programming Menu Programming ProceduresTitle and Contents of Programming Menu TEC Store How to enter charactersMenu PLU Data EditSet tare limit PLU Data SettingAuto Code Ingredient Message Nutrition Setting When entering PLU#, be careful of the following Set the Daily Value Table Daily Value Max digits Contents of Daily valueMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort Menu Item No Verifies PLU data stored in the scale PLU Verifying LabelAddress and Commercial Message Setting Message construction Message display time Combination MessageThank YOU ANK YOU Call AGA Scrolling Flashing Curtaining Scrolling up Scrolling downThank YOU Thank YOU CallGrade Line Special InformationVendor Number Speed KEY SettingSetting Department/Vendor Number Department NumberBy pressing Key Print FormatFormat No Label Format Number TableDATE/TIME Setting Menu Item NoCMT Operations PL-3 Operation Error code during PL-3 operationTransmission Item List Item #CMT IN-LINE/LOCAL Transmission Delay Time TableLON System Initial #0 #19, SL-9000N only Cancel Retry ContinueData Transmission Price Address SL-9000N only② By Count Format Default Bar Code FormatBAR Code Format ① Weigh or Fix Price FormatPLU # UPC # PC/D Flag PLU # UPC # PC/D Price WeightAdditional 234 235 Additional 7,8 238 Additional 9,10 239 Title No Format Additional 221Additional 231 232 Additional 233Transferring Logo Data SL-9000N onlyVerify SL-9000=CMT Error message during data transmission Idiom SettingVendor Setting Free Format Setting Key functionsEnter SP-INFO/NET WT Logo Frequent Shopper Print coordinate How to access Report menu Programmed Data Verification ReportsMenu Set the zone PLU #. Ex. PLU #100 ~108 R S X Z Password SecuritySetting Password and Protect Menu R S× ー × Calling Menu by Entering Password How to access REG., M.DOWN, or Rewrap menu Operating ProceduresWeighing Operation Menu REG., M.DOWN, or Rewrap Mode WeighFIX Price Operation for US Type only By Count Operation For To check the remaining number, clear the PLU and press Key Print Count OperationExample B When operating in Fix or By Count mode Set the number of labels. Max labels Enter the PLU # PLU Issuing Labels with NET Weight Statement for US Type onlySample label 14-10 TARE/SAVE Function Procedures Calling and Printing Grade Lines Logo Calling and Printing LogosSelecting Print Item Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Unit Price Change and G.Line/LOGO Call Key Label Issue Stop or CancelTotals Overflow error occurs when Key is pressed to issueDpt # Visual Commodity LibraryFloating Vendor Subtotal Price deletionTotal Operation How to access Read or Reset menuEx. Report Menu Hourly Total ReportGrand Total Report PLU Total ReportFor Enter PLU Total Vendor Total ReportProgramming Mode Error Message TableReport and Reset Mode Label lssue ModeLON System Mode Cleaning the Print Head Before You Call for Service Troubleshooting