14. OPERATING PROCEDURES
14.6 TARE/SAVE FUNCTION PROCEDURES
14.6TARE/SAVE FUNCTION PROCEDURES
Menu: REG., M.DOWN, or REWRAP
Mode: WEIGH or FIX (Tare % function is available in WEIGH mode only.)
There aretwo kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare “. The SAVE key is used to save the tare, unit price, and PLU data after taking a commodity from the platter.
Place a container on the platter.
(Ex. 0.200 lb)
Press:
Enter the PLU #.
0.200 lb |
T
1 | 0 | 0 |
|
|
|
2 | 0 | 0 |
|
|
|
T
Press:
Place a container on the platter
Tare %
1 | 0 | 0 |
|
|
|
% |
Press:
PLU
Tare %
% |
The PLU data and tare are | SAVE |
saved. | |
Place a commodity on the |
|
platter. |
|
(Ex. 1.000 lb) |
|
MANUAL: | :AUTO |
| |
* |
|
| The label is issued. |
1 | 0 | 0 |
|
|
|
% |
Remove the Commodity together with the container.
| Press: |
| C |
|
|
| ||
CA type |
|
|
| US type | ||||
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PLU | Press: |
| 0 | |||||
|
|
|
|
|
|
|
|
|
T
Press:
Press:
Press: | C | |
|
|
|
|
|
|
Remove the commodity together with the container.
PLU
Press:
NOTES: 1. Tare subtraction is available up to 2.000 lb. for the US type, and up to 1.000kg (2.205lb) for the CA/QR type. When tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare. (Net
2.Preset tare must be a multiple of 2 g for CA/QR type (Kg scale) and a multiple of 0.005 lb for US/CA type (Lb scale).
3.The tare % function is available when the Initial Setting
4.When a commodity is placed on the platter and the calculated tare exceeds the maximum, a “TARE WEIGH OVER” error will occur.