Panasonic EW3153W manual Measurement, Press the On/Off and Start button on the main unit

Page 20

Taking a Reading (continued)

Measurement

The entire display will light for approx.

1 second.

The pressure cuff will be tightened automatically.

The heart mark will blink when pulse is detected during pressurization.

1Press the On/Off and Start button on the main unit.

(1)After the entire display on the wireless display has been lit, the pressure cuff will be tightened automatically.

(2)Pressurization will be performed automatically and measurements will be taken.

*It may take about 1 second for the wireless display to turn on after pressing the On/Off and the Start button. This is not abnormal.

*The angle of the main unit may change slightly while pressurizing. This will not affect accuracy.

2When measurement has been completed, the blood pressure and pulse values will be displayed.

The cuff will loosen after the measurement result has been shown for about 5 seconds.

• The blood pressure indication ( mark) will flash for 6 seconds then stay lit. If the measurement is high, it will also flash for 6 seconds to indicate high blood pressure. (See page 22.)

• The mark will light. (For storing measurement values, see page 24.)

The pulse rate value is the beats per minute calculated based on the pulse rate during measurement.

Themark is displayed when pulse rate could not be measured.

3Remove your arm from the main unit.

4To switch off the blood pressure monitor, press the On/Off and Start button on the main unit.

If you forget to switch it off, the blood pressure monitor will switch off automatically after approximately 2 minutes.

When the Adjust button “2” on the wireless display is pressed, indications disappears but the power of the main unit is still on for about 2 minutes.

19English

Image 20
Contents Instructions English Table of Contents Introduction Basics of Blood PressureImportant Instructions Before Use English Precautions to Ensure Safe, Reliable Operation English Blood Pressure Categories Systolic Blood Pressure SBPPreparations Prior to Taking Measurements Battery cover for main unit IR transmitter on both sides Connector Arm supportParts Identification Main unit View from TopWireless display View from Bottom AM/PM comparison buttonWhen Using the Main Unit with Batteries Turn the main unit overInserting the Batteries into the Wireless Display Setting the time and date Adjust the monthAdjust the date Adjust the hourPut the main unit on a table in front of you AdviceTaking a Reading Posture to obtain accurate measurements Sit quietly and relax while taking measurementsDo not take measurements Positions of the main unit and the wireless display Arm is appliedRemove your arm from the main unit MeasurementPress the On/Off and Start button on the main unit Movement detection function Irregular pulse function Alarm function signals high blood pressure When an Error Occurs During MeasurementIf the pressure cuff comes off Storing blood pressure readings Press the Memory/Recall button Memory storage is completedCalling up readings from memory Press the Memory/Recall buttonDeleting all data stored in memory Press the Adjust button 2 to switch off the unit Press the buttonAfter Use Specifications Mark does not light when an arm is moved Is still higher than usual When should I measure my blood pressure?Mark was displayed, I retried the measurement Care and Maintenance Symptom Possible cause TroubleshootingDisplay Status before error Cause and solution Press the ring portion on the outside One Panasonic Way 1H-1 Secaucus, NJ No.1 EN, SP