Panasonic EW3153W manual If the pressure cuff comes off

Page 24

Taking a Reading (continued)

To interrupt measurements quickly

Press the Quick air release button.

If pressure cuff will not deflate quickly enough even if the On/Off and Start button is pressed, press and hold the quick air release button on top of the unit. The air will be released in approximately 4 seconds.

If the pressure cuff comes off:

1With the belt and seam downwards, slide the pressure cuff into the main unit.

2Press the pressure cuff into the groove of the main unit. Either the front or the back can be attached first.

Seam

Belt

With the belt and seam downwards, slide the pressure cuff into the main unit.

Pressure cuff

Groove

Check that the pressure cuff is inserted in the groove on the main unit.

*When re-attaching, be sure not to touch the inside of the main unit where the pressure cuff has been removed.

Doing so may result in an accident or injury.

23English

Image 24
Contents Instructions English Table of Contents Introduction Basics of Blood PressureImportant Instructions Before Use English Precautions to Ensure Safe, Reliable Operation English Blood Pressure Categories Systolic Blood Pressure SBPPreparations Prior to Taking Measurements Battery cover for main unit IR transmitter on both sides Connector Arm supportParts Identification Main unit View from TopWireless display View from Bottom AM/PM comparison buttonWhen Using the Main Unit with Batteries Turn the main unit overInserting the Batteries into the Wireless Display Setting the time and date Adjust the monthAdjust the date Adjust the hourAdvice Taking a ReadingPut the main unit on a table in front of you Posture to obtain accurate measurements Sit quietly and relax while taking measurementsDo not take measurements Positions of the main unit and the wireless display Arm is appliedMeasurement Press the On/Off and Start button on the main unitRemove your arm from the main unit Movement detection function Irregular pulse function Alarm function signals high blood pressure When an Error Occurs During MeasurementIf the pressure cuff comes off Storing blood pressure readings Press the Memory/Recall button Memory storage is completedCalling up readings from memory Press the Memory/Recall buttonDeleting all data stored in memory Press the Adjust button 2 to switch off the unit Press the buttonAfter Use Specifications Mark does not light when an arm is moved When should I measure my blood pressure? Mark was displayed, I retried the measurementIs still higher than usual Care and Maintenance Troubleshooting Display Status before error Cause and solutionSymptom Possible cause Press the ring portion on the outside One Panasonic Way 1H-1 Secaucus, NJ No.1 EN, SP