Furuno SC-50 manual Error messages con’t from previous, Data ERR

Models: SC-50

1 82
Download 82 pages 38.78 Kb
Page 63
Image 63

4. MAINTENANCE, TROUBLESHOOTING

Error messages (con’t from previous page)

Error Message

Meaning

Remedy

BATTERY ALM!

Voltage of battery in processor

Have battery replaced at

 

unit is low.

earliest convenience.

DATA ERR!

GPS data (from the GPS receiver

Check navigator.

 

in the processor unit) is lost for

 

 

one minute. Heading output is

 

 

stopped and the heading

 

 

indication shows “- - -“.

 

DGPS ERROR!

DGPS data (from external DGPS

Ship may not be within DPGS

 

receiver) is lost for one minute.

service area.

GPS DATA ERROR!

GPS data (from internal GPS

Conduct diagnostic test1 and

 

receiver) is lost for one minute.

check if NG appears for results

 

Heading output is stopped and the

for GPS receivers GPS1, GPS2

 

heading indication shows “- - -“.

and GPS3.

GPS NO FIX!

No GPS data.

Check antenna cable.

HDG ERROR!

Heading error

Request service.

NO HEADING OUTPUT!

GPS heading error continues for

Press any key to try to restore

 

five minutes. In this case heading

normal operation.

 

output is stopped and the heading

 

 

indication shows “- - -“.

 

RAM ERROR!

RAM problem

Request service.

RATE ERROR!

Data output stopped.

Request service.

RATE ERROR(YAW)!

Yaw sensor problem

Request service.

RATE ERROR(ROLL)!

Roll sensor problem

Request service.

RATE ERROR(PITCH)!

Pitch sensor problem

Request service.

COMMUNICATION ERR!

Communication between display

Request service.

 

unit and processor has been

 

 

interrupted.

 

WAAS ERROR

WAAS data lost for one minute.

Request service.

ROM ERROR!

ROM problem

Request service.

4-10

Page 63
Image 63
Furuno SC-50 manual Error messages con’t from previous, Data ERR