Furuno SC-50 manual Data OUT1 menu, sentences, Baud rate options

Models: SC-50

1 82
Download 82 pages 38.78 Kb
Page 41
Image 41

3.OPERATION

5.Choose SENTENCE and then press the [ENT] key.

 

 

DATA OUT1

 

 

 

 

HDT

VTG

VHW

HDM

GGA

VBW

ROT

GNS

HVE

ATT

GLL

ZDA

VDR

 

 

DATA OUT1 menu, sentences

6.Use the Omnipad to choose the sentence to process and then press the [ENT] key.

HDT: True heading (required for radar, AIS, ECDIS, etc.)

HDM: Magnetic heading (Some boaters may want magnetic heading when the boat is fitted with only a magnetic compass without correction of deviation and variation. HDM is obtained in this equipment by adding the magnetic variation to HDT automatically.)

ROT: Rate-of-turn data

ATT: True heading, pitching, rolling (FURUNO’s proprietary sentence)

VDR: Set and drift

VTG: Course over ground and ground speed

GGA: Global positioning system (GPS) fix data

GNS: GNSS fix data

GLL: Geographic position, latitude/longitude

VHW: Water speed and heading

VBW:

Dual ground/water speed

HVE:

Pitch and roll data (FURUNO’s proprietary sentence)

ZDA

Time and date

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

7.Use the Omnipad to choose OFF or ON as appropriate and then press the [ENT] key. Sentences selected for output are marked with an asterisk.

8.Choose item desired and then press the [ENT] key.

9.Choose ON or OFF as appropriate and then press the [ENT] key.

10.Press the [MENU] key to return to the DATA OUT1 menu.

11.Choose BAUD RATE and then press the [ENT] key.

4800BPS

9600BPS

19200BPS

38400BPS

Baud rate options

3-10

Page 41
Image 41
Furuno SC-50 manual Data OUT1 menu, sentences, Baud rate options