Furuno SC-50 manual Others Menu, Others menu, HDG Restoration options, HDG Backup options

Models: SC-50

1 82
Download 82 pages 38.78 Kb
Page 50
Image 50

3. OPERATION

3.11OTHERS Menu

The OTHERS menu chooses whether to output last-used heading data, and smoothes rate of turn meter reading (rate-of-turn meter required).

1.Press the [MENU] key to display the main menu.

2.Choose OTHERS and then press the [ENT] key.

OTHERS

HOLD HDG DATA: OFF

HDG RESTORATION : MAN

HDG BACKUP : 5MIN

Others menu

3.Choose HOLD HDG DATA and then press the [ENT] key.

4.Choose ON to use, at power on, last-used heading until current heading is calculated. Last-used heading flashes to inform you that it is unreliable.

5.Press the [ENT] key.

6.Choose HDG RESTORATION and then press the [ENT] key.

MAN

AUTO

HDG RESTORATION options

7.Use the Omnipad to choose how to restore GPS signal, automatically or manually, and then press the [ENT] key.

8.HDG BACKUP is selected; press the [ENT] key.

OFF

ON

HDG BACKUP options

9.Enter how long to wait before stopping heading output, using the Omnipad.

10.Press the [ENT] key followed by the [DISP] key to close the menu.

3-19