2. INSTALLATION

2.6Initial Settings

Follow the procedures in this section to enter initial settings.

NOTICE

Improper menu settings may stop output of data and display the message "RATE ERROR." Be sure to enter correct data.

2.6.1Confirming satellite status; choosing mounting method

1. Turn on the processor unit and then press the [MENU] key to show the menu.

MAIN MENU

 

 

 

SATELLITE

ALARMS

 

 

MESSAGES

 

 

WAAS/DGPS

GPS SETUP

 

I/O SETUP

SYS SETUP

 

INST MENU

SOFT VER.

 

ERASE

OTHERS

 

TRIP MENU

 

Main menu

2.Use the Omnipad () to choose “INST MENU” and then press the [ENT] key.

INSTALLATION SETUP

MOUNTING : WALL

DIRECTION : A

LANGUAGE : ENG

ROLL OFFSET : 0.0

PITCH OFFSET : 0.0

Installation setup menu

3.Confirm that “MOUNTING” is selected and then press the [ENT] key.

4.Use the Omnipad to choose the mounting method: “FLOOR”, “WALL” or “INVERT” as appropriate.

5.Press the [ENT] key.

6.Choose “DIRECTION” and then press the [ENT] key.

7.Use the Omnipad to choose mounting direction (“A ”, “B ”, “C” or “D”) as appropriate. Refer to section 2.3.1.

8.Press the [ENT] key.

9.Press the [SAT STATUS] key.

2-19

Page 28
Image 28
Furuno SC-50 Initial Settings, Confirming satellite status choosing mounting method, Main menu, Installation setup menu