4. MAINTENANCE, TROUBLESHOOTING
4.7Replacement of Fuse
The 3 A fuse on the POWER Board inside the processor unit protects the equipment from overcurrent and reverse polarity of the power supply. If the fuse blows, have a qualified technician check the fuse.
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage to the equipment or cause fire.
4.8Error Messages
The alarm sounds for equipment error and is accompanied by a flashing exclamation mark (). Press any key to silence the alarm. The exclamation mark remains on the screen until the cause for error is eliminated. Find the cause for the alarm(s) as follows:
1.Press the [MENU] key to open the menu.
2.Choose MESSAGES and then press the [ENT] key.
MESSAGES
GPS DATA ERROR!
Message display
3.Press the [DISP] key to close the menu. Error messages
Error Message | Meaning | Remedy |
ABORTING! | GPS heading error continues for | Check for obstruction. |
| one minute. For example, satellite |
|
| cannot be acquired because of |
|
| unfavorable environment. |
|
ABORTING CALC! | GPS signal lost for one minute. | Press any key to try to restore |
|
| normal operation. |
BACKUP ERROR!(DISP) | Corrupted backup data found in | Default settings are |
| display unit at power on. | automatically restored. |
BACKUP | Corrupted backup data found at | Default settings are |
ERROR!(PRCSSR) | processor unit at power on. | automatically restored. |