IBM x Series 200 manual Error Code/Symptom

Models: x Series 200

1 152
Download 152 pages 50.59 Kb
Page 99
Image 99

Error Code/Symptom

 

FRU/Action

 

 

 

201-XXX-999

1.

See error text for failing DIMMs

(Multiple DIMM failure, see

 

 

error text.)

 

 

 

 

 

202-XXX-001

1.

Microprocessor CPU 1

(Failed System Cache test)

 

 

 

 

 

206-XXX-000

1.

Cable

(Failed Diskette Drive test)

2.

Diskette Drive

 

 

 

 

3.

System Board

 

 

 

215-XXX-000

1.

CD-ROM Drive Cables

(Failed IDE CD-ROM test)

2. CD-ROM Drive

 

 

 

 

3.

System Board

 

 

 

217-XXX-000

1.

Fixed Disk 1

(Failed BIOS Fixed Disk test)

 

 

Note:

If RAID is

 

 

 

configured, the fixed

 

 

 

disk number refers to

 

 

 

the RAID logical

 

 

 

array.

 

 

 

 

 

217-XXX-001

1.

Fixed Disk 2

(Failed BIOS Fixed Disk test)

 

 

Note:

If RAID is

 

 

 

configured, the fixed

 

 

 

disk number refers to

 

 

 

the RAID logical

 

 

 

array.

 

 

 

 

 

217-XXX-002

1.

Fixed Disk 3

(Failed BIOS Fixed Disk test)

 

 

Note:

If RAID is

 

 

 

configured, the fixed

 

 

 

disk number refers to

 

 

 

the RAID logical

 

 

 

array.

 

 

 

 

 

264-XXX-0NN

1.

Tape Cartridge, if user executed the Read/Write Tape Drive test (XXX = 256)

(NN = SCSI ID of failing Tape

2.

SCSI or power cable connected to the tape drive with SCSI ID NN

 

 

Drive)

 

3.

Tape drive with SCSI ID NN – refer to Help and Service Information appendix of

 

 

 

tape drive’s User Guide.

 

 

4.

I/O Legacy Board or SCSI Controller – run SCSI Controller diagnostic to

 

 

 

determine of SCSI bus is functioning properly.

 

 

 

264-XXX-999

1.

See error messages/text in the PC Doctor error log for detailed information on

(Errors on multiple tape

 

each individual tape drive error.

 

 

drives, see error text for more

 

 

info)

 

 

 

 

 

 

 

Symptom-to-FRU index 91

Page 99
Image 99
IBM x Series 200 manual Error Code/Symptom