Symptom-to-FRU index

Symptom-to-FRU index

This index supports xSeries 200 servers.

Notes:

1.Check the configuration before you replace a FRU. Configuration problems can cause false errors and symptoms.

2.The default configuration can be loaded by starting the system and then pressing the reset button four times, waiting 15 seconds between each press. Once the configuration has reset to the default, it must be saved in Setup to be stored in CMOS.

3.For IBM devices not supported by index, refer to the manual for that device.

4.Always start with “Chapter . General checkout,” on page 1.

The Symptom-to-FRU lists symptoms, errors, and the possible causes. The most likely cause is listed first. Use this Symptom-to-FRU index to help you decide which FRUs to have available when servicing the computer. The POST BIOS displays POST error codes and messages on the screen.

Beep symptoms

Beep symptoms are short tones or a series of short tones separated by pauses (intervals without sound). See the following examples.

Note: One beep after successfully completing POST indicates the system is

 

 

 

 

functioning properly.

 

 

 

 

Beeps

 

 

 

Description

 

 

 

 

1-2-3

 

One beep

 

 

• A pause (or break)

 

 

Two beeps

 

 

• A pause (or break)

 

 

Three Beeps

 

 

 

 

4

 

Four continuous beeps

 

 

 

 

 

 

 

 

 

Beep/Symptom

 

 

FRU/Action

 

 

 

 

 

1-1-3

 

 

1.

Battery

(CMOS write/read test

2.

System Board

 

 

failed)

 

 

 

 

 

 

 

 

1-1-4

 

 

1.

System Board

(BIOS EEPROM

 

 

 

checksum failed)

 

 

 

 

 

 

 

 

1-2-1

 

 

1.

System Board

(Programmable

 

 

 

Interval Timer failed)

 

 

 

 

 

 

 

 

© Copyright IBM Corp. 2000

85

Page 93
Image 93
IBM x Series 200 manual Symptom-to-FRU index, Beep symptoms