ServeRAID
For ServeRAID error codes and procedures, refer to the Hardware Maintenance
Manual for the particular RAID adapter in the system being serviced.
Undetermined problems
You are here because the diagnostic tests did not identify the failure, the Devices List is incorrect, or the system is inoperative.
Note: A corrupt CMOS can cause undetermined problems.
If power problems are suspected:
1.
2.Be sure the system is cabled correctly.
3.Remove or disconnect the following (one at a time) until you find the failure
•Any external devices
•Surge suppressor device (on the computer)
•Modem, printer, mouse, or
•Each adapter
•Drives
•Memory Modules (Minimum requirement = one 128 MB DIMM)
Note: Minimum operating requirements are:
a.1 Power Supply
b.System Board
c.1 Microprocessor
d.1 Terminator Card in Slot 2
e.1 Memory Module (minimum of 1 DIMM in slot labeled DIMM 1)
4.
Power Supply
System Board
Notes:
1.If the problem goes away when you remove an adapter from the system, and replacing that adapter does not correct the problem, suspect the system board, then the power supply.
2.If you suspect a networking problem and all the system tests pass, suspect a network cabling problem external to the system.
100Hardware Maintenance Manual: xSeries 200