Error Code/Symptom

 

FRU/Action

 

 

 

301-XXX-000

1.

Keyboard

(Failed Keyboard test)

 

 

 

 

 

405-XXX-000

1.

Verify that Ethernet is not disabled in BIOS.

(Failed Ethernet test on

2.

System Board

 

 

controller on the System

 

 

Board)

 

 

 

 

 

405-XXX-00N

1.

Adapter in PCI slot N.

(Failed Ethernet test on

2.

System Board

 

 

adapter in PCI slot N)

 

 

 

 

 

415-XXX-000

1.

Cable

(Failed Modem test)

2.

Modem

 

 

 

3.

System Board

 

 

 

 

 

 

Error symptoms

 

 

 

 

 

General

 

FRU/Action

 

 

 

CD is not working properly.

1.

Clean the CD.

 

2.

Run CD-ROM diagnostics.

 

3.

CD-ROM Drive

 

 

 

CD-ROM drive tray is not

1.

Insert the end of a paper clip into the manual tray-release opening.

working.

2.

Run CD-ROM diagnostics.

 

(The server must be

3.

CD-ROM Drive

powered-on.)

 

 

 

 

 

CD-ROM drive is not

1.

Run Configuration/Setup, enable primary IDE channel.

recognized.

2.

Check cables and jumpers.

 

 

3.

Check for correct device driver.

 

4.

Run CD-ROM diagnostics.

 

5.

CD-ROM drive

 

6.

System Board

 

 

 

Power switch does not work.

1.

Verify that switch number 5 of switch block is Off.

 

2.

Power Switch Assembly

 

3.

System Board

 

 

 

CD-ROM drive cable is not

1.

Make sure CD-ROM drive cable is plugged in.

plugged in.

 

 

 

 

 