Table 1. Features and Specifications.
Server features

Table 1. Features and Specifications.

Microprocessor: Supports one

Power supply:

microprocessor (depending on your

One 330 watt (90-240 V ac)

model)

• Intel® Pentium® III with 256 KB

Video:

 

Level-2 cache and MMX™

 

S3 Savage 4 AGP video adapter

 

(MMX2) technology

 

or

• Compatible with SVGA and

 

 

VGA

• Intel® Celeron® with 128 KB

 

• 8 MB SDRAM video memory

 

Level-2 cache and MMX™

 

 

 

 

(MMX2) technology

Size:

 

 

Memory:

Height: 470 mm (18.5 in.)

Minimum: 64 MB

Depth: 508 mm (19.9 in.)

Maximum: 1.5 GB

Width: 165 mm (6.5 in.)

• Type: PC133 MHz, ECC SDRAM,

Weight: approximately 19.5 Kg

 

unregistered DIMMs only

 

(43 lb.) when fully configured or

• Slots: 3 dual inline

 

15.9 Kg (35 lb.) minimum

 

 

Drives: (depending on your model)

Integrated functions:

 

 

Diskette: 1.44 MB

10BASE-T/100BASE-TX

 

Ethernet controller on the

CD-ROM: IDE

 

 

system board

 

 

 

Hard disk drive

Two serial ports

 

 

Tape drive

One parallel port

 

 

Expansion bays:

Two USB ports

 

 

• Two 5.25-in. bays (one CD-ROM

Keyboard port

 

 

 

drive installed)

Mouse port

• Two 3.5-in. bays (one diskette

MIDI port

 

drive installed)

Audio ports

 

 

• Three 3.5-in. slim-high bays

 

— Line out

 

available

 

 

 

— Line in

 

 

 

PCI expansion slots:

 

— Mic

 

 

 

• Three 33 MHz/32-bit on the

Dual-channel bus mastering

 

system board (some models come

 

IDE controller

 

with a SCSI adapter installed)

 

 

• Two 33 MHz/32-bit on the PCI

Acoustical noise emissions:

 

Bus extender board

Sound power, idling: 6.6 bel

AGP slot: Accelerated graphics port

 

maximum

Sound power, operating: 6.8 bel

(AGP)

 

 

 

maximum

 

 

 

 

Environment:

Air temperature:

Server on: 10° to 35° C (50.0°

to 95.0° F). Altitude: 0 to 914 m (2998.7 ft.)

Server on: 10° to 32° C (50.0°

to 89.6° F). Altitude: 914 m (2998.7 ft.) to 2133 m (6998.0 ft.)

Server off: 10° to 43° C (50.0° to 109.4° F). Maximum altitude: 2133 m (6998.0 ft.)

Humidity:

Server on: 8% to 80%

Server off: 8% to 80%

Heat output:

Approximate heat output in British Thermal Units (Btu) per hour

Minimum configuration: 341 Btu (100 watts)

Maximum configuration: 1604 Btu (470 watts)

Electrical input:

Sine-wave input (50-60 Hz) required

Input voltage low range:

Minimum: 90 V ac

Maximum: 137 V ac

Input voltage high range:

Minimum: 180 V ac

Maximum: 265 V ac

Input kilovolt-amperes (kVA) approximately:

Minimum: 0.08 kVA

Maximum: 0.52 kVA

The design of the 200 takes advantage of advancements in data storage and memory management. The server combines:

Impressive performance using an innovative approach to microprocessor utilization

The server comes with one Celeron® or Pentium® III microprocessor installed.

4Hardware Maintenance Manual: xSeries 200

Page 12
Image 12
IBM x Series 200 manual Features and Specifications