Error Code/Symptom |
| FRU/Action |
|
|
|
187 | 1. | Set serial number in Setup |
(VPD serial number not set.) | 2. | System Board |
|
| |
|
|
|
188 | 1. | Run Configuration/Setup |
(Bad EEPROM CRC #2) | 2. | System Board |
|
| |
|
|
|
189 | 1. | Run Configuration/Setup, enter the administrator password |
(Three attempts were made to | 2. | System Board. |
|
| |
access the server with invalid |
|
|
passwords) |
|
|
|
|
|
201 | 1. | Run memory diagnostics. |
(Memory test error, see | 2. | DIMM |
|
| |
"Memory Settings" on page | 3. | System Board |
31.) If the server does not |
|
|
have the latest level of BIOS |
|
|
installed, update the BIOS to |
|
|
the latest level and run the |
|
|
diagnostic program again. |
|
|
|
|
|
229 | 1. | Microprocessor |
(Cache error) |
|
|
|
|
|
289 | 1. | Run Configuration/Setup, if disabled by user |
(DIMM has been disabled by | 2. | Disabled DIMM, if not disabled by user. |
|
| |
user or system, see "Memory |
|
|
Settings" on page 31.) |
|
|
|
|
|
301 | 1. | Keyboard |
(Keyboard or keyboard | 2. | System Board |
|
| |
controller error) |
|
|
|
|
|
303 | 1. | System Board |
(Keyboard controller error) | 2. | Keyboard |
|
| |
|
|
|
602 | 1. | Diskette |
(Invalid diskette boot record) | 2. | Diskette Drive |
|
| |
| 3. | Cable |
| 4. | System Board |
|
|
|
604 | 1. | Run Configuration/Setup and Diagnostics |
(Diskette drive error) | 2. | Diskette Drive |
|
| |
| 3. | Drive Cable |
| 4. | System Board |
|
|
|
662 | 1. | Run Configuration/Setup and Diagnostics |
(Diskette drive configuration | 2. | Diskette Drive |
|
| |
error) | 3. | Drive Cable |
| 4. | System Board |
|
|
|