IBM x Series 200 manual Hardware Maintenance Manual xSeries

Models: x Series 200

1 152
Download 152 pages 50.59 Kb
Page 104
Image 104

Error Code/Symptom

 

FRU/Action

 

 

 

187

1.

Set serial number in Setup

(VPD serial number not set.)

2.

System Board

 

 

 

 

 

188

1.

Run Configuration/Setup

(Bad EEPROM CRC #2)

2.

System Board

 

 

 

 

 

189

1.

Run Configuration/Setup, enter the administrator password

(Three attempts were made to

2.

System Board.

 

 

access the server with invalid

 

 

passwords)

 

 

 

 

 

201

1.

Run memory diagnostics.

(Memory test error, see

2.

DIMM

 

 

"Memory Settings" on page

3.

System Board

31.) If the server does not

 

 

have the latest level of BIOS

 

 

installed, update the BIOS to

 

 

the latest level and run the

 

 

diagnostic program again.

 

 

 

 

 

229

1.

Microprocessor

(Cache error)

 

 

 

 

 

289

1.

Run Configuration/Setup, if disabled by user

(DIMM has been disabled by

2.

Disabled DIMM, if not disabled by user.

 

 

user or system, see "Memory

 

 

Settings" on page 31.)

 

 

 

 

 

301

1.

Keyboard

(Keyboard or keyboard

2.

System Board

 

 

controller error)

 

 

 

 

 

303

1.

System Board

(Keyboard controller error)

2.

Keyboard

 

 

 

 

 

602

1.

Diskette

(Invalid diskette boot record)

2.

Diskette Drive

 

 

 

3.

Cable

 

4.

System Board

 

 

 

604

1.

Run Configuration/Setup and Diagnostics

(Diskette drive error)

2.

Diskette Drive

 

 

 

3.

Drive Cable

 

4.

System Board

 

 

 

662

1.

Run Configuration/Setup and Diagnostics

(Diskette drive configuration

2.

Diskette Drive

 

 

error)

3.

Drive Cable

 

4.

System Board

 

 

 

96Hardware Maintenance Manual: xSeries 200