Error Code/Symptom

 

FRU/Action

 

 

 

015-XXX-198

1.

Remove USB devices from USB1 and USB2

(USB device connected

2. Re-run test

 

 

during USB test)

3.

System Board

 

 

 

020-XXX-000

1.

System Board

(Failed PCI Interface test)

 

 

 

 

 

030-XXX-000

1.

System Board

(Failed Internal SCSI interface

 

 

test)

 

 

 

 

 

030-XXX-00N

1.

Adapter in Slot N

(Failed SCSI test on PCI slot

 

 

N. Check system error log

 

 

before replacing a FRU.)

 

 

 

 

 

035-XXX-099

1.

No adapters were found.

 

2.

If adapter is installed re-check connection.

 

 

 

035-XXX-S99

1.

Adapter

(Failed RAID test on PCI slot

2.

SCSI Backplane

 

 

S. S = number of failing PCI

3.

Cable

slot. Check System Error Log

 

 

before replacing a FRU.)

 

 

 

 

 

035-XXX-SNN

1.

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.

(Check System Error Log

 

 

before replacing a FRU. S =

 

 

number of failing PCI slot;

 

 

NN = SCSI ID of failing fixed

 

 

disk.)

 

 

 

 

 

035-253-S99

1.

ServeRAID Adapter in slot S is not configured properly. Obtain the basic and

(RAID adapter initialization

 

extended configuration status and refer to the ServeRAID Hardware Maintenance

 

Manual for more information.

failure)

2.

Cable

 

 

3.

Adapter

 

 

 

075-XXX-000

1.

Power Supply

(Failed Power Supply test)

 

 

 

 

 

089-XXX-001

1.

Microprocessor

(Failed Microprocessor test)

 

 

 

 

 

180-XXX-003

1.

System Board

(Failed System Board LED

 

 

test)

 

 

 

 

 

201-XXX-0NN

1.

DIMM Location J1-J4

(Failed Memory test, see

2.

Memory card

 

 

"Memory Settings" on page

 

 

31.) NN = DIMM location.

 

 

 

 

 

90Hardware Maintenance Manual: xSeries 200

Page 98
Image 98
IBM x Series 200 manual Hardware Maintenance Manual xSeries