FRU information (service only)

FRU information (service only)

Field Replacement Units (FRUs) should be replaced by qualified service personnel only.

Hard disk drive cage

Before you begin:

Read “Safety information” on page 105.

Review the information in “Before you begin” on page 38.

To remove the hard disk drive cage, do the following:

1.Power-off the server, if it is on.

2.Unplug the server.

3.Remove the front bezel (see “Removing the bezel” on page 41).

4.Remove the cover (see “Removing the side cover” on page 40).

5.Remove the support bracket (see “Removing the support bracket assembly” on page 42).

6.Remove any hard disk drives or drive fillers from the drives.

7.Disconnect the hard disk drive cables from the system board.

8.Remove the screws from the front of the hard disk drive cage.

9.Move the cage slightly in and up until it is free of the chassis and lift it out of the server.

Note: Take care not to dislodge the memory when you remove the cage.

Power supply

Before you begin:

Read “Safety information” on page 105.

Review the information in “Before you begin” on page 38.