IBM x Series 200 manual Installing a hard disk drive in bay 5, 6, or

Models: x Series 200

1 152
Download 152 pages 50.59 Kb
Page 59
Image 59
Installing a hard disk drive in bay 5, 6, or 7

Note: Make sure to route the signal cable so that it does not block the air flow to the rear of the drives or over the microprocessor.

9.If you have other options to install or remove, do so now.

10.Connect one of the power cables from the power supply into the back of the drive. The connectors are keyed and can be inserted only one way.

11.Replace the support bracket assembly and reconnect the fan cable to the connector (SYSFA3) on the system board. See “System board internal cable connectors” on page 36 for the location of the fan cable connector.

12.Reinstall the side cover, see “Installing the cover” on page 59 for details.

13.Reconnect the external cables and power cords; then, turn on the peripheral devices and the server.

Installing a hard disk drive in bay 5, 6, or 7

Drive cage retention tab

Drive cage release tab

Complete the following steps to install a hard disk drive in bay 5, 6, or 7.

Attention: When you handle ESD-sensitive devices, take precautions to avoid damage from static electricity, see “Handling static-sensitive devices” on page 39.

1.Read the information in “Preinstallation steps (all bays)” on page 49.

2.Turn off the server and peripheral devices and disconnect all external cables and power cords; then, remove the cover (see “Removing the side cover” on page 40 for details).

3.Remove the support bracket assembly. See “Removing the support bracket assembly” on page 42.

4.Remove the support bracket assembly and disconnect the fan cable from the connector (SYSFA3) on the system board. See “Removing the support bracket

Installing options 51

Page 59
Image 59
IBM x Series 200 manual Installing a hard disk drive in bay 5, 6, or