IBM x Series 200 manual Installing internal drives, Internal drive bays

Models: x Series 200

1 152
Download 152 pages 50.59 Kb
Page 55
Image 55
Installing internal drives

2.Connect the SCSI signal cable to the adapter and one or more of the signal cable connectors to the rear of the SCSI devices.

3.Connect the SCSI activity indicator cable to the adapter and to the SCSI LED connector (J3) on the system board. See “System board internal cable connectors” on page 36 for the location of this connector.

Note: If you are installing a ServeRAID adapter and already have a SCSI adapter installed, remove the SCSI adapter and store it for future use.

4.If you have other adapters or options to install or remove, do so now.

5.Rotate the front adapter support bracket to the closed (locked) position.

6.Reinstall the rear adapter retaining bracket; then, rotate the bracket to the closed (locked) position.

7.Reinstall the side cover, see “Installing the cover” on page 59 for details.

8.Reconnect the external cables and power cords; then, turn on the peripheral devices and the server.

Installing internal drives

Different types of drives enable your server to read multiple types of media and store data in different formats. Depending on your server model, you might have one or more of the following drives installed.

Diskette

Hard disk

CD-ROM

Tape

Internal drive bays

Your server comes with an IDE CD-ROM drive installed in bay 1, a 3.5-in., 1.44 MB diskette drive in bay 3, and a hard disk drive in bay 5. For instructions on installing drives in bays 1 and 3, see “CD-ROM drive” on page 76 and “Floppy disk drive” on page 77.

Note: The illustrations in this document might differ slightly from your hardware.

Installing options 47

Page 55
Image 55
IBM x Series 200 manual Installing internal drives, Internal drive bays