IBM x Series 200 manual Error Code/Symptom

Models: x Series 200

1 152
Download 152 pages 50.59 Kb
Page 103
Image 103

Error Code/Symptom

 

FRU/Action

 

 

 

114

1.

Failing adapter

(Adapter read-only memory

2.

Run diagnostics

 

 

error)

 

 

 

 

 

129

1.

Microprocessor

(Internal cache error)

 

 

 

 

 

151

1.

Run Diagnostics

(Real time clock error)

2.

Battery

 

 

 

3.

System Board

 

 

 

161

1.

Run Configuration/Setup

(Real time clock battery error)

2.

Battery

 

3.

System Board

 

 

 

162

1.

Run Configuration/Setup

(Device Configuration Error)

2.

Battery

 

 

Note: Be sure to load the

3.

Failing Device

 

 

default settings and

4.

System Board

any additional

 

 

desired settings; then,

 

 

save the configura-

 

 

tion.

 

 

 

 

 

163

1.

Run Configuration/Setup

(Real-Time Clock error)

2.

Battery

 

 

 

3.

System Board

 

 

 

164

1.

Run Configuration/Setup

(Memory configuration

2.

DIMM

 

 

changed, see "Memory

3.

System Board

Settings" on page 31.)

 

 

 

 

 

175

1.

System Board

(Hardware error)

 

 

 

 

 

176, 177, 178

1.

Run Configuration/Setup

(Security hardware error)

2.

System Board

 

 

 

 

 

184

1.

Run Configuration/Setup

(Power-on password

2.

System Board

 

 

corrupted)

 

 

 

 

 

185

1.

Run Configuration/Setup

(Drive startup sequence

2.

System Board

 

 

information corrupted)

 

 

 

 

 

186

1.

Run Configuration/Setup

(Security hardware control

2.

System Board

 

 

logic failed)

 

 

 

 

 

Symptom-to-FRU index 95

Page 103
Image 103
IBM x Series 200 manual Error Code/Symptom