Error Code/Symptom |
|
|
|
| FRU/Action | |
|
|
|
|
|
| |
01298101 |
|
| 1. | Ensure all microprocessors are the same stepping level and cache size. | ||
(Bad update data for |
| 2. | Microprocessor | |||
|
|
|
|
| ||
microprocessor) |
|
|
|
|
| |
|
|
|
|
|
| |
01298200 |
|
| 1. | Ensure all microprocessors are the same speed. | ||
(Microprocessor speed |
|
|
|
|
| |
mismatch) |
|
|
|
|
| |
|
|
|
|
|
| |
I9990301 |
| 1. | Hard Disk Drive | |||
(Fixed boot sector error) |
| 2. | If RAID system, refer to the Hardware Maintenance Manual for the specific RAID | |||
|
| adapter. |
| |||
|
|
|
|
| ||
|
|
| 3. | SCSI Backplane | ||
|
|
| 4. | Cable |
| |
|
|
| 5. | System Board | ||
|
|
|
|
|
| |
I9990305 |
| 1. | Install operating system to hard disk drive. | |||
(Fixed boot sector error, no |
|
|
|
|
| |
operating system installed) |
|
|
|
|
| |
|
|
|
|
|
|
|
I9990650 |
| 1. | Check cable |
| ||
(AC power has been restored) |
| 2. | Check for interruption of power supply | |||
|
|
| 3. | Power Cable | ||
|
|
|
|
| ||
Other numbers |
| Follow instructions on screen. | ||||
|
|
|
|
| ||
|
|
|
|
|
|
|
Processor board LEDs |
| |||||
| Table 16. . |
|
|
| ||
|
|
|
|
|
| |
|
|
| LED |
| Cause | |
|
|
|
|
|
| |
| Fan |
|
| 1. | Replace the fan assembly. | |
|
|
|
| |||
| Memory |
| 1. Replace the DIMM indicated by the lit DIMM error. | |||
|
|
|
|
| ||
| CPU |
|
| 1. If a microprocessor LED is on for a microprocessor connector that has | ||
|
|
|
|
|
| a terminator card installed instead of a microprocessor, the |
|
|
|
|
|
| microprocessors are not installed in the correct order. See “Removing |
|
|
|
|
|
| and installing a microprocessor” on page 54 for information about the |
|
|
|
|
|
| correct order for installing microprocessors and VRMs. |
|
|
|
|
| 2. | Turn off the server, reseat the microprocessor, and restart the server. |
|
|
|
|
| 3. | Replace the microprocessor. |
|
|
|
|
| ||
| VRM |
|
| 1. Turn off the server, reseat the VRM indicated by the lit VRM error | ||
|
|
|
|
|
| LED, and restart the server. |
|
|
|
|
| 2. | Replace the VRM |
|
|
|
|
|
|
|