1 152
Download 152 pages 50.59 Kb
Page 107
Image 107

Error Code/Symptom

 

 

 

 

FRU/Action

 

 

 

 

 

 

01298101

 

 

1.

Ensure all microprocessors are the same stepping level and cache size.

(Bad update data for

 

2.

Microprocessor

 

 

 

 

 

microprocessor)

 

 

 

 

 

 

 

 

 

 

 

01298200

 

 

1.

Ensure all microprocessors are the same speed.

(Microprocessor speed

 

 

 

 

 

mismatch)

 

 

 

 

 

 

 

 

 

 

 

I9990301

 

1.

Hard Disk Drive

(Fixed boot sector error)

 

2.

If RAID system, refer to the Hardware Maintenance Manual for the specific RAID

 

 

adapter.

 

 

 

 

 

 

 

 

 

3.

SCSI Backplane

 

 

 

4.

Cable

 

 

 

 

5.

System Board

 

 

 

 

 

 

I9990305

 

1.

Install operating system to hard disk drive.

(Fixed boot sector error, no

 

 

 

 

 

operating system installed)

 

 

 

 

 

 

 

 

 

 

 

 

I9990650

 

1.

Check cable

 

(AC power has been restored)

 

2.

Check for interruption of power supply

 

 

 

3.

Power Cable

 

 

 

 

 

Other numbers

 

Follow instructions on screen.

 

 

 

 

 

 

 

 

 

 

 

 

Processor board LEDs

 

 

Table 16. .

 

 

 

 

 

 

 

 

 

 

 

 

LED

 

Cause

 

 

 

 

 

 

 

Fan

 

 

1.

Replace the fan assembly.

 

 

 

 

 

Memory

 

1. Replace the DIMM indicated by the lit DIMM error.

 

 

 

 

 

 

CPU

 

 

1. If a microprocessor LED is on for a microprocessor connector that has

 

 

 

 

 

 

a terminator card installed instead of a microprocessor, the

 

 

 

 

 

 

microprocessors are not installed in the correct order. See “Removing

 

 

 

 

 

 

and installing a microprocessor” on page 54 for information about the

 

 

 

 

 

 

correct order for installing microprocessors and VRMs.

 

 

 

 

 

2.

Turn off the server, reseat the microprocessor, and restart the server.

 

 

 

 

 

3.

Replace the microprocessor.

 

 

 

 

 

 

VRM

 

 

1. Turn off the server, reseat the VRM indicated by the lit VRM error

 

 

 

 

 

 

LED, and restart the server.

 

 

 

 

 

2.

Replace the VRM

 

 

 

 

 

 

 

Symptom-to-FRU index 99