Replacing Belt
Lift Agitator Up
Soulever l’agitateur Unidad del agitador
➢Replace belt whenever a burning rubber smell caused by excessive slippage occurs.
➢Place
➢Remove lower plate.
➢Remove agitator by carefully lifting out.
Motor Shaft |
|
Arbre d’entraînement |
|
du moteur | |
Eje del motor | |
| Selector Shaft |
| Arbre du sélecteur |
| tapis/plancher |
| Eje del selector |
|
End Cap
| Bouchon | |
Groove | Tapa del | |
extremo | ||
Ouverture | ||
| ||
Ranura |
|
➢Remove worn or broken belt.
➢Clean agitator and reinstall the two
(2) end caps.
➢Loop new belt (Panasonic Type UB8 only) around motor shaft and brush pulley; see illustration for correct belt routing.
➢Reinstall agitator back into nozzle housing grooves.
➢After reinstalling the agitator, turn it by hand to make sure that belt is not twisted or pinched and that all rotating parts turn freely.
➢Reinstall lower plate.
- 34 -