Error #3 AC Current High

• Occurs if the AC module output current exceeds the operational threshold.

Nominal Voltage 240 Volt AC

Nominal Voltage 208 Volt AC

 

 

 

 

Max. Output AC current

1.27A AC

Max. Output AC current

1.44A AC

 

 

 

 

Ex) AC Current High Screen

App Message Screen

Web Event Screen

Check for other messages.

Problem may stem from instability of the utility service.

Check that proper cables are used for the system and that the AC connector is connected correctly.

Error #4 Inverter Failure

Occurs if AC module malfunctions..

Ex) Inverter Failure Screen

App Message Screen

Web Event Screen

Check for other messages.

Problem may stem from instability of the system.

Check that proper cables are used for the system and that the AC connector is connected correctly.

13

Image 13
Contents Troubleshooting Guide AC module Product SpecificationsDimension Parameter Range Clearing Time s Response to Abnormal ConditionsDedicated Cables Table of Contents Safety Symbols SafetyGateway Ex App Messages Screen Messages and AlertsDate AC module ID Message type Ex Web Array View ScreenEx Voltage Low Screen Ex Web Event ScreenApp Message Screen X12 An array of AC modules Nominal Frequency 60Hz 59.3 to 60.5Hz Hawaii 57 to 60.5Hz Ex Frequency Changing Too Fast ScreenEx AC Frequency Low Error #2 DC Current High Error #1 DC Voltage HighEx DC Voltage High Screen Ex DC Current High ScreenError #4 Inverter Failure Error #3 AC Current HighEx AC Current High Screen Ex Inverter Failure ScreenEx Temperature Protection Screen Error #5 Temperature ProtectionAlert Gfdi Ex Gfdi ScreenFactors that Affect Power Line Communication Gateway and Communication IssuesProblems Checking AC Module through the Smartphone App Checking for Interferences to the Power Line Communication Solving Connection Issues in the Gateway Connecting the Gateway to a Remote RouterChanging the EnerBox Registering Additional AC Modules to the GatewayRelocating a Gateway with Completed AC Module Registration Registering a Replacement AC Module to the GatewayNetwork Configuration Troubleshooting Memo Memo
Related manuals
Manual 36 pages 62.6 Kb