LG Electronics LGxxxA1C-B3 manual Product Specifications, AC module

Page 2

Product Specifications

AC module

DC Input

Parameter

Section

 

Value

 

Power

Max.

295 W

300W

 

305W

Tolerance

3 %

3 %

 

3 %

 

 

Voltage

Open Circuit

39.7 V

39.8 V

 

40.0 V

Max. Power Point

31.8 V

32.0 V

 

32.1 V

 

 

Current

Short Circuit

9.85 A

9.98 A

 

10.10 A

Max. Power Point

9.28 A

9.40 A

 

9.52 A

 

 

Efficiency

Relative Reduction

 

< 2.0%

 

 

Note : *Relative efficiency reduction in respect to irradiance

 

 

 

Note : Rated electrical characteristics are within 10 percent of above figures.

PV module was measured at STC (Standard Test Condition : Irradiation 1,000W/m2, Cell temp. 77°F(25°C), 1,5AM)

AC Output

Parameter

 

Section

240VAC

 

208VAC

 

 

AC Continuous1)

280W (@DC Module 295W) / 285W (@DC Module

Power

 

300W) / 290W (@DC Module 305W)

 

 

 

 

Inverter Rated Continuous

305W

 

300W

Voltage

 

Rated

240V (211 ~ 264 V)

 

208V (187 ~ 229V)

Current

 

Rated

1.27A

 

1.44A

 

Max. Fault Current

 

77A

 

 

 

Efficiency

 

Nominal

60 Hz (59.3 ~ 60.5 Hz)

 

Extended

57.0 Hz ~ 60.5 Hz

 

 

 

Power Factor

 

> 0.95

CEC Weighted Efficiency

96.5%

 

96.0%

(California Energy Commission)

 

 

 

 

Max. Number of AC Modules

12 ea

 

11ea

1)Pmax (AC) = Max. Input DC Power x CEC Efficiency

Protection

Ground Fault Detection and Interrupt (GFDI)

Applied

Fuse

2A

 

 

CAUTION : FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE,

REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE

Over Current Protection Device (OCPD)

20A

2

Image 2
Contents Troubleshooting Guide Product Specifications AC moduleDimension Dedicated Cables Response to Abnormal ConditionsParameter Range Clearing Time s Table of Contents Safety Safety SymbolsGateway Date AC module ID Message type Messages and AlertsEx App Messages Screen Ex Web Array View ScreenApp Message Screen Ex Web Event ScreenEx Voltage Low Screen X12 An array of AC modules Ex AC Frequency Low Ex Frequency Changing Too Fast ScreenNominal Frequency 60Hz 59.3 to 60.5Hz Hawaii 57 to 60.5Hz Ex DC Voltage High Screen Error #1 DC Voltage HighError #2 DC Current High Ex DC Current High ScreenEx AC Current High Screen Error #3 AC Current HighError #4 Inverter Failure Ex Inverter Failure ScreenAlert Gfdi Error #5 Temperature ProtectionEx Temperature Protection Screen Ex Gfdi ScreenGateway and Communication Issues Factors that Affect Power Line CommunicationProblems Checking AC Module through the Smartphone App Checking for Interferences to the Power Line Communication Connecting the Gateway to a Remote Router Solving Connection Issues in the GatewayRegistering Additional AC Modules to the Gateway Changing the EnerBoxRegistering a Replacement AC Module to the Gateway Relocating a Gateway with Completed AC Module RegistrationNetwork Configuration Troubleshooting Memo Memo