3-1-11 Registering a Replacement AC Module to the Gateway
If you need toexchange an AC module, follow the steps below.
1Enter LGElectronics (initial password) on the blank box in the figure and press the EnerBox Group chage button to return the gateway to the initial condition.
Check that the PLC LED has turned red.
2Press Back button. Wait for a minute and check that PLC LED is now turned to green. Then. press MAC Address List and check if the additional AC modules have been listed.
If you can’t see the additional AC modules, connect the gateway to another outlet near the distribution panel and search for the unlisted AC modules.
3Press Delete button to delete the exchanging AC module MAC address.
4Press Registration button to finish.
LGElectronics
3-1-12 Relocating a Gateway with Completed AC Module Registration
After the EnerBox is connected to a 120VAC outlet of the new location, enter into AC Module Status and check that all previously registered MAC addresses colors are shown in black.
MAC address color is red : Unreliable link detection.
If some MAC addresses colors are red, the EnerBox must be connected to a different AC outlet.