Lifescan Blood Glucose Monitor manual 900AM, Time and Date

Page 44
6.01.00
M-MOVEC-CHANGE

TIME AND DATE

In the set-up mode, use the M button to choose the Time option. The current time will show. Press the C button to change the time; the hour and AM or PM will flash. Press the C button again to advance the hour to the correct set- ting. Now press the M button and the minutes will flash. Use the C button to

change the minutes.

 

Press the M button to

9:00AM

see the new time setting.

 

M-MOVE C-CHANGE

To set the date, press the M button in set-up mode. The current date will show. Press the C button; the year will flash. Press the C button again to change the year to the correct setting. Now press the M button and the month will flash. Use the C button to change the month. Press the M button and the day will flash. Press the C but- ton to change the day.

Press the M button again to display the new date setting.

43

Image 44
Contents Owner’s Booklet Page Table of Contents Solving Problems Introduction Precautions and Limitations ONE Touch Profile Blood Glucose Meter Page ONE Touch Test Strips Important Test Strip Information Turn on the meter Setting the SystemCoding the Meter Match the Code Numbers Code the MeterCheck Strip Test Insert the check strip Remove the check strip Turn the check strip over and insert it back into the meter Important Check Strip Information Control Solution Test Do a control solution testImportant Control Solution Test Information Use only One Touch Normal Control SolutionInsert a test strip Apply control solution Result appears within 45 seconds Testing Your Blood Detailed Test ProcedureGetting a Drop of Blood Never share a lancet with another personAdjust Puncture Depth Cock the Penlet Plus Sampler Wash Your HandsGet a Drop of Blood Helpful tipsPage Remove the Lancet Cleaning the Penlet Plus Sampler STEP- BY- Step Test Procedure CodeWait Not Enough Blood Retest Apply blood to the test spotRemove the test Strip from the meter Accurate results in 45 seconds Do YOU Event Labelling To select an event label, press the C but Using the Meter Memory Entering the MemoryNodata Recalling ResultsInterm Changing Meter Settings Entering the SET-UP Options ModeOFF OFF Beep Prompts900AM Time and DateEvent Averaging Insulin Prompt Change the insulin typeInsulin Programming Change the insulin units000 Carbohydrate CountingDisplay Language Time Format Date FormatComma Decimal SeparatorExiting the SET-UP Mode Unit of MeasureSolving Problems Test Procedure MessagesSide Check Ketones CALL. DR Test Ketones Error Messages Message Problem What to doClean Error Not Enough Blood Retest Message Problem Redo Taking Care of Your Meter Cleaning the Meter Remove the test strip holder from the meterClean the test area Replace the Test Strip Holder Replacing the Batteries BATTRY` Replace NOW Insert the new AAA batteries into the battery compartment Remove the old batteriesSpecifications Performance CharacteristicsWarranty Five-Year WarrantyInsulin Types Units will Advance on the Display AS Follows1995 IFD/OB/OTP
Related manuals