Olympus FV300 manual Easy exchange between display methods, Image tool bar, Thumbnail display

Page 5

Easy exchange between display methods

Independent navigation bars for each image window enable the display method to be changed quickly and easily.

Image tool bar

X-Y-Z scanning operations and time- lapse observations both produce multiple images, which can be displayed in sequence simply by clicking the sequential mode button. Channel selection and image zooming are also available on the same menu.

Thumbnail display

Data stored in the gallery window are displayed as thumbnails for easy viewing.

Tiling display function for see-at-a- glance comparison of multiple images

The FV300's live tiling function, which is especially valuable in time course experiments, allows observations of multiple images or changes in the specimen while the experiment is in progress. Images in series (e.g. XYt or XYZ) can be freely displayed.

Scanning unit set-up monitor display

Single monitor display is also possible.

Sequential scanning to prevent cross talk

Sequential scanning may be used to minimize the fluorescence cross talk often seen between channels in multicolored samples. This is achieved by exciting each fluorochrome independently, one dye at a time. With the AOTF function, line sequential scanning is available as well.

* Once optimized: steps q-r can be performed easily

q Excited by only HeNe633

w Excited by only Kr568

e Excited by only Ar488

rComposition

Human colon crypt

Nuclei (Blue) TO-PRO-3

Actin (Green) Alexa 488

APC gene product (Red) Alexa 568

Christine Anderson,

Laboratory of Prof. Ray White,

Hunstsman Cancer Institute, Utah

4

Image 5
Contents FV300 FV300-IX71configuration Page Software Graphical User Interface Image tool bar Easy exchange between display methodsThumbnail display Scanning unit set-up monitor displayHigh-speed 4 frames/sec image acquisition Time CourseVersatile line scanning modes have many uses Superior slice patching systemRatio imaging to analyze 2-wavelength images Input/output of external trigger signal440nm diode laser can be added for CFP/YFP Fret imaging Papp for Frap Application Multi-point time lapse system Features Measure up to 254 pointsHigh-precision XY stage scanning Flexible scanning conditions3D Imaging Easy Z axis operation and settingRegions/Min-Max Mode Threshold ModeColocalization Link with patch clamping dataStructure of PtK2 cell Applications GalleryFluorescent Proteins Fluorochrome 300 400 500 600Short Pass Band Pass Long Pass Specifications ISO9001