Emerson 708 manual Mounting Considerations, Piping, Insulation Side View

Page 19

Reference Manual

00809-0100-4708, Rev AD September 2012

Rosemount 708

Mounting Considerations

1.Mounting bands should be inspected periodically and retightened if necessary. Some loosening may occur after initial installation due to thermal expansion/contraction.

2.The waveguide must be in direct contact with the pipe.

3.Insulate process piping to minimize ambient temperature effects (see Figure 3-4). Insulation thickness over the top of the waveguide foot should not exceed 2.54 cm (1-in).

4.For best results, mount the transmitter within 15.24 cm (6 in.) of the equipment to be monitored.

5.The stainless steel mounting bands could be affected by stress corrosion and potentially fail when in the presence of chlorides.

6.The transmitter should be installed such that steam or other high temperature fluids do not directly impinge the housing of the device.

7.If installing the device on a steam trap, the device should be installed on the upstream side of the trap.

Figure 3-4. Piping, Insulation

Side View

1 in.

3-3

Image 19
Contents Reference Manual Rosemount 708 Wireless Acoustic TransmitterPage International Rosemount 708 Wireless Acoustic TransmitterCustomer Central National Response CenterExplosions could result in death or serious injury Shipping considerations for wireless productsTable of Contents Appendix B Appendix aAppendix C Section Overview Safety MessagesGeneral OverviewTransmitter ConsiderationsRecommended Practices Wireless ConsiderationsPower Up Sequence Antenna PositionElectrical MechanicalEnvironmental Service Support RECYCLING/DISPOSAL ProductSafety Messages Device Configuration Section ConfigurationField Communicator Device Network ConfigurationAMS Wireless Configurator AMSFast Key Sequence Remove Power ModuleField Communicator Menu Tree Hart Menu TreeMounting SectionTransmitter Alignment Piping, Insulation Side View Mounting ConsiderationsRosemount Verify Operation CommissioningAMS Suite Wireless Configurator Smart Wireless Gateway ExplorerSmart Wireless Gateway Network Settings TroubleshootingKey Function Sequence Menu Items Field Communicator UseSafety Messages Operation Operation and MaintenanceAMS Device Manager Overview Screen Normal Conditions AlertsAlert Levels Device Alert ConfigurationAlert Setup Alert Setup Install and LearnAlert Setup Manual Alert Setup Guided User Alert SetupHandling Considerations Power Module ReplacementEnvironmental Considerations Shipping Considerations Overview Safety Messages TroubleshootingConfiguration Troubleshooting Symptom Device Troubleshooting Corrective ActionsWireless Troubleshooting Specifications Appendix a Specifications and Reference DataFunctional Specifications Physical Specifications Performance Specifications Wireless Output Specifications Rosemount 708 Direct Mount Dimensional DrawingsOrdering Information Appendix B Product Certifications Standards Hazardous Locations CertificatesNorth American Certifications Special Conditions for Safe UseBrazilian Certifications IECEx System CertificationsSafe Use Conditions CMaster-PRINTEDCOPIESAREUNCONTROLLED- RosemountProprietary Effective Range Appendix C Recommended PracticesRosemount Page Asia Pacific Private Limited 00809-0100-4708, Rev AC September