Emerson 708 manual Section, Mounting

Page 17

Reference Manual

00809-0100-4708, Rev AD September 2012

Rosemount 708

Section 3

Mounting

SAFETY MESSAGES

Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1

Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (). Please refer to the following safety messages before performing an operation preceded by this symbol.

Warnings

Failure to follow these installation guidelines could result in death or serious injury:

Only qualified personnel should perform the installation

Explosions could result in death or serious injury.

Before connecting a Field Communicator in an explosive atmosphere, make sure that the instruments are installed in accordance with intrinsically safe field wiring practices

Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.

This device must be installed to ensure a minimum antenna separation distance of 20 cm (8 in.) from all persons.

MOUNTING

1.

Locate the 708 on a section of piping as close as possible to the

 

 

equipment to be monitored. Align the waveguide of the transmitter as

 

 

shown in Figure 3-1and Figure 3-2.

 

2.

The mounting location should be free of foreign matter and corrosion

 

 

to ensure good contact between the piping and the waveguide.

 

3.

Tighten each clamp to 10.2 N-m (90 in-lb). Trim the excess clamp

 

 

band material to prevent unwanted acoustic noise.

 

4.

If commissioning the device, install the Green Power Module (see

 

 

Figure 3-3 on page 3-2).

 

5.

Ensure that the Power Module cover is fully tightened to prevent

 

 

moisture ingress. The lip of the polymer Power Module cover should

be in contact with the surface of the polymer enclosure to ensure a proper seal. Do not over tighten.

3-1

Image 17
Contents Reference Manual Rosemount 708 Wireless Acoustic TransmitterPage Customer Central Rosemount 708 Wireless Acoustic TransmitterNational Response Center InternationalExplosions could result in death or serious injury Shipping considerations for wireless productsTable of Contents Appendix C Appendix aAppendix B Section Overview Safety MessagesTransmitter OverviewConsiderations GeneralPower Up Sequence Wireless ConsiderationsAntenna Position Recommended PracticesEnvironmental MechanicalElectrical Service Support RECYCLING/DISPOSAL ProductSafety Messages Device Configuration Section ConfigurationAMS Wireless Configurator Device Network ConfigurationAMS Field CommunicatorFast Key Sequence Remove Power ModuleField Communicator Menu Tree Hart Menu TreeMounting SectionTransmitter Alignment Piping, Insulation Side View Mounting ConsiderationsRosemount Verify Operation CommissioningAMS Suite Wireless Configurator Smart Wireless Gateway ExplorerSmart Wireless Gateway Network Settings TroubleshootingKey Function Sequence Menu Items Field Communicator UseSafety Messages Operation Operation and MaintenanceAMS Device Manager Overview Screen Normal Conditions AlertsAlert Setup Device Alert ConfigurationAlert Setup Install and Learn Alert LevelsAlert Setup Manual Alert Setup Guided User Alert SetupEnvironmental Considerations Power Module ReplacementHandling Considerations Shipping Considerations Overview Safety Messages TroubleshootingWireless Troubleshooting Symptom Device Troubleshooting Corrective ActionsConfiguration Troubleshooting Functional Specifications Physical Specifications Appendix a Specifications and Reference DataSpecifications Performance Specifications Wireless Output Specifications Rosemount 708 Direct Mount Dimensional DrawingsOrdering Information Appendix B Product Certifications North American Certifications Hazardous Locations CertificatesSpecial Conditions for Safe Use StandardsSafe Use Conditions IECEx System CertificationsBrazilian Certifications CMaster-PRINTEDCOPIESAREUNCONTROLLED- RosemountProprietary Effective Range Appendix C Recommended PracticesRosemount Page Asia Pacific Private Limited 00809-0100-4708, Rev AC September