Emerson 708 manual Section Configuration, Safety Messages Device Configuration

Page 13

Reference Manual

00809-0100-4708, Rev AD September 2012

Rosemount 708

Section 2

Configuration

SAFETY MESSAGES

Warnings

DEVICE CONFIGURATION

Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 Device Network Configuration . . . . . . . . . . . . . . . . . . . . . page 2-2 Remove Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-3 HART Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-4

Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Information that potentially raises safety issues is indicated by a warning symbol (). Please refer to the following safety messages before performing an operation preceded by this symbol.

Explosions could result in death or serious injury:

Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the Product Certifications section for any restrictions associated with a safe installation.

Before connecting a Field Communicator in an explosive atmosphere, ensure the instruments are installed in accordance with intrinsically safe wiring practices.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions. This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.

This device must be installed to ensure a minimum antenna separation distance of 20 cm (8 in.) from all persons.

The Power Module may be replaced in a hazardous area. The Power Module has surface resistivity greater than one gigaohm and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent a potential electrostatic charging hazard.

Polymer enclosure has surface resistivity greater than one gigaohm. Care must be taken during transportation to and from the point of installation to prevent a potential electrostatic charging hazard.

Remove the power module cover and connect to the HART communication terminals for configuration.

The Rosemount 708 will receive HART communication from a handheld 375/475 Field Communicator (Field Communicator) or AMS Wireless Configurator. When using a Field Communicator, any configuration changes must be sent to the transmitter using the Send key (F2). AMS Wireless Configurator configuration changes are implemented when the Apply button is clicked.

2-1

Image 13
Contents Reference Manual Rosemount 708 Wireless Acoustic TransmitterPage Customer Central Rosemount 708 Wireless Acoustic TransmitterNational Response Center InternationalExplosions could result in death or serious injury Shipping considerations for wireless productsTable of Contents Appendix B Appendix aAppendix C Section Overview Safety MessagesTransmitter OverviewConsiderations GeneralPower Up Sequence Wireless ConsiderationsAntenna Position Recommended PracticesElectrical MechanicalEnvironmental Service Support RECYCLING/DISPOSAL ProductSafety Messages Device Configuration Section ConfigurationAMS Wireless Configurator Device Network ConfigurationAMS Field CommunicatorFast Key Sequence Remove Power ModuleField Communicator Menu Tree Hart Menu TreeMounting SectionTransmitter Alignment Piping, Insulation Side View Mounting ConsiderationsRosemount Verify Operation CommissioningAMS Suite Wireless Configurator Smart Wireless Gateway ExplorerSmart Wireless Gateway Network Settings TroubleshootingKey Function Sequence Menu Items Field Communicator UseSafety Messages Operation Operation and MaintenanceAMS Device Manager Overview Screen Normal Conditions AlertsAlert Setup Device Alert ConfigurationAlert Setup Install and Learn Alert LevelsAlert Setup Manual Alert Setup Guided User Alert SetupHandling Considerations Power Module ReplacementEnvironmental Considerations Shipping Considerations Overview Safety Messages TroubleshootingConfiguration Troubleshooting Symptom Device Troubleshooting Corrective ActionsWireless Troubleshooting Specifications Appendix a Specifications and Reference DataFunctional Specifications Physical Specifications Performance Specifications Wireless Output Specifications Rosemount 708 Direct Mount Dimensional DrawingsOrdering Information Appendix B Product Certifications North American Certifications Hazardous Locations CertificatesSpecial Conditions for Safe Use StandardsBrazilian Certifications IECEx System CertificationsSafe Use Conditions CMaster-PRINTEDCOPIESAREUNCONTROLLED- RosemountProprietary Effective Range Appendix C Recommended PracticesRosemount Page Asia Pacific Private Limited 00809-0100-4708, Rev AC September