Emerson 708 manual Performance Specifications Wireless Output Specifications

Page 34

Rosemount 708

Reference Manual

00809-0100-4708, Rev AD September 2012

Performance Specifications

Wireless Output Specifications

Weight

708 with power module -0.595 kg (1.31 lb)

708 without power module - 0.445 kg (0.98 lb)

Enclosure ratings

NEMA 4X and IP66/67

Vibration Effect

Tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz 0.21 mm displacement peak amplitude/60-2000 Hz 3g).

Temperature Limits

Ambient Limit -40 °C to 85 °C (-40 °F to 185 °F)

Storage Limit -40 °C to 85 °C (-40 °F to 185 °F)

Temperature Derating

Process Temperature (°C)

Max Ambient (°C)

260

41

240

45

220

49

200

53

180

57

160

61

140

64

120

68

100

72

85

75

ElectroMagnetic Compatibility (EMC)

All Models:

Meets all relevant requirements of EN 61326-2-3:2006

Acoustic Level

0-255 counts

Temperature

-40 to 260 °C (-40 to 500 °F)

A-2

Image 34
Contents Rosemount 708 Wireless Acoustic Transmitter Reference ManualPage National Response Center Rosemount 708 Wireless Acoustic TransmitterCustomer Central InternationalShipping considerations for wireless products Explosions could result in death or serious injuryTable of Contents Appendix B Appendix aAppendix C Safety Messages Section OverviewConsiderations OverviewTransmitter GeneralAntenna Position Wireless ConsiderationsPower Up Sequence Recommended PracticesElectrical MechanicalEnvironmental Service Support Product RECYCLING/DISPOSALSection Configuration Safety Messages Device ConfigurationAMS Device Network ConfigurationAMS Wireless Configurator Field CommunicatorRemove Power Module Fast Key SequenceHart Menu Tree Field Communicator Menu TreeSection MountingTransmitter Alignment Mounting Considerations Piping, Insulation Side ViewRosemount Commissioning Verify OperationSmart Wireless Gateway Explorer AMS Suite Wireless ConfiguratorTroubleshooting Smart Wireless Gateway Network SettingsField Communicator Use Key Function Sequence Menu ItemsOperation and Maintenance Safety Messages OperationAlerts AMS Device Manager Overview Screen Normal ConditionsAlert Setup Install and Learn Device Alert ConfigurationAlert Setup Alert LevelsAlert Setup Guided User Alert Setup Alert Setup ManualHandling Considerations Power Module ReplacementEnvironmental Considerations Shipping Considerations Troubleshooting Overview Safety MessagesConfiguration Troubleshooting Symptom Device Troubleshooting Corrective ActionsWireless Troubleshooting Specifications Appendix a Specifications and Reference DataFunctional Specifications Physical Specifications Performance Specifications Wireless Output Specifications Dimensional Drawings Rosemount 708 Direct MountOrdering Information Appendix B Product Certifications Special Conditions for Safe Use Hazardous Locations CertificatesNorth American Certifications StandardsBrazilian Certifications IECEx System CertificationsSafe Use Conditions CMaster-PRINTEDCOPIESAREUNCONTROLLED- RosemountProprietary Appendix C Recommended Practices Effective RangeRosemount Page 00809-0100-4708, Rev AC September Asia Pacific Private Limited