Multi-Link ML-001, ML-100 manual Installing Door / Window Sensors, Mounting the Sensor, Testing

Page 17

HOME AUTOMATION

INSTALLATION (ML-100A Only)

Control Module [1] is represented by zone LED 1

This row :

Buttons for

Learning Control Module

Installing Door / Window Sensors

Window / Door Sensor is used to monitor doors or windows that open and close. When these doors / windows are open or closed, the sensors will transmit a signal to the control panel to notify the user. These sensors consist of 2 parts, one is the transmitter, the other is the magnet.

Transmitter Magnet

Part 2 Learn signal from Control Panel to Control Module

Step

 

Keys

 

Function

Description

Note

 

 

 

 

 

 

1

 

Press and hold

Enter

 

LED on the Control Module

 

 

the learn button

Programming

 

will flash indicating it is in

 

 

on the Control

 

mode

 

learn mode.

 

 

Module until its

 

 

 

 

 

 

LED starts to

 

 

 

 

 

 

 

flash.

 

 

 

 

 

 

 

 

 

 

 

 

2

 

[6] to [0]

 

Transmit an ON

Refer to the

After [X] is entered, you

 

 

 

 

signal for the

chart below to

will hear [Device X On]

 

 

 

 

 

 

 

 

 

 

selected device

determine which

indicating you have trans-

 

 

 

 

 

from the Control

button [6] to [0]

mitted an ON signal for

 

 

 

 

 

Panel to the

to press.

device X, where X is the

 

 

 

 

 

Control Module.

You should

Control Module Location.

 

 

 

 

 

 

 

transmit the “ON”

The LED on the Control

 

 

 

 

 

 

 

command for the

Module should be off,

 

 

 

 

 

 

 

selected device.

indicating it has learned

 

 

 

 

 

 

 

 

the signal, you may now

 

 

 

 

 

 

 

 

release the learn button

 

 

 

 

 

 

 

 

and the LED will stay on

 

 

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL MODULE

 

TRANSMIT

 

 

 

LOCATION

 

 

BUTTON [X]

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

9

 

 

 

5

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

42

Before installing the sensor, remove the battery isolator by pulling out the yellow tab. Once the isolator is removed, the corresponding zone LED on the control panel will flash and buzzer will beep. If the magnetic contact is closed, the beeping will stop.

Note:

-Both Window/Door Sensors have been programmed at the factory. They are Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the beeping and zone LED to determine which one is zone 1 and which is zone 2.

Mounting the Sensor

The transmitters should be mounted on the door frame or window frame by double sided tape. The magnet should be mounted on the door or window by either double sided tape or screws. Make sure the magnet is aligned with the red marking on the transmitter. If the surface of the frame is flat enough, double- sided foam tape is sufficient, otherwise, it is recommended to screw the mounting plate to the frame, then apply double sided tape. After mounting the sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the AAA+ logo is in the upright position.

Magnet on the left

Magnet on the right

Mounting plate

Double-sided Sensor

 

 

and screws

foam tape

 

 

(optional)

 

Testing:

After mounting the sensor, test the sensor by opening and closing the door or window. Open the door or window will result in the followng:

1.Beeping - The number of beep represents the zone number.

2.Zone LED flashing - Number of flash represents the sensor number.

15

Image 17
Contents Email support@skylinkhome.com Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel 905Fax 905 Home Smart Center Important Safety Instructions EMC Declaration of ConformitySystem Configuration ContentOperation Disarming a triggered control panelFCC Information Consumer Information IntroductionOverview System Configuration Control Module SW-100 Introduction AccessoriesControl Module SW-101U UK, SW-101F French, SW-101G German Emergency Dialer AD-433SInstalling the Console InstallationRepeater RP-434 Door/Window Sensor WD-101Water Sensor FS-101 Garage Door MonitorTM Sensor GS-101Programming Passwords Trouble ShootingChanging Passwords Order to change the password, follow the procedures belowControl Panel Questions SolutionsPhone Number Programming Home Automation Testing Phone NumbersEvent Trigger Contact ID Phone numberZone LED Description Account Number ProgrammingErase Control Modules Deactivating the Digital DialerOperation Part 2 Learn signal from Control Panel to Control Module Installing Door / Window SensorsTesting Mounting the SensorInsert Battery Installing Motion SensorPart 1 Learn signal from Control Module to Control Panel Table E Zone LED status for learning control moduleTo indicate the light has been turned on Learn Control ModulesOperation Alert ModeAdvanced Programming Erase SensorsTable C MuteLearn Sensors Continue Learn Sensors System StatusArming the System Disarming the system Erase Keychain / Keypad RemotesLearn Keychain / Keypad Remotes Disarming a triggered control panelDisarming under Duress Panic To enable alert zone feature, follow the instructions belowSystem Failure Phone Line FailureIt is recommend to enable alert zone if Low BatterySensor Failure Control PanelAuto Mute To enable auto mute feature, follow the instructions belowExample CommunicationReceiving the Emergency Call Calling in when you are away from home To access the control panel away from homeSystem Armed Alarm Mode Remote Operation by TelephoneRemote Phone Operations Beep / AlarmSystem Disarmed Alert Mode