Multi-Link ML-100, ML-001 manual Disarming a triggered control panel, Disarming under Duress

Page 24

OPERATION

2.You must enter a valid password, either the Master Password, or Secondary Password to disarm the system before entry delay expires.

3.When a valid password is entered, you will hear “System Disarmed” and the entry delay beeping will stop, the ARM LED will be off.

Note:

-The control panel can also be disarmed remotely when nobody is home, with a touch tone phone. Please refer to “Remote Operation by Telephone” on page 27.

-If 3 consecutive incorrect passwords are entered, alarm will sound immediately, the control panel will be in panic mode, and start calling the emergency phone numbers.

Disarming a triggered control panel

If "System Panic" is announced from the control panel after it has been disarmed, that means the alarm was triggered when it was in armed mode. Follow the procedures below to set the control panel back to standby mode.

1.If the alarm was caused by sensor(s), there will be flashing LEDs and beeping indicating which sensor(s) triggered the alarm. You may want to check the condition of the triggered sensor(s), the sensor(s) may be damaged if there were break-ins.

2.You need to reset the sensor manually by triggering it twice, i.e. open and then close a door / window sensor, or walk in front of the motion sensor. The LED representing that sensor will stop flashing after it receives the signal from the sensor.

3.You must now enter the password again on the control panel or press the disarm button on the keychain remote, as an acknowledgement of the alarm event. This will set the control panel back to standby mode.

Disarming under Duress

If you are forcibly compelled to disarm the control panel, you may enter the Duress Password. Entering the duress password will terminate the entry delay, i.e. no more entry delay beeping. But the control panel will silently call the emergency phone numbers for help. The called party will hear the voice announcement “System Panic”.

Note:

- The default duress password is [3838].

22

ADVANCED PROGRAMMING

Learn Keychain / Keypad Remotes

Additional keychain or keypad remotes can be programmed to the control panel. Maximum of 5 keychain/keypad remotes can be programmed to the control panel.

-Keychain or keypad remotes should be programmed to Device 6 to Device 0.

Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8, 9, or 0, which is the bottom row of the numeric keypad of the control panel.

Step

 

Keys

 

Function

Description

 

Note

 

 

 

 

 

 

 

1

 

[PROG]

Enter Program-

Enter master

 

3 beeps for valid

 

 

[MPIN]

 

ming mode

password to

 

password. 1 long beep

 

 

 

 

 

 

programming mode

 

for invalid password.

2

 

[4]

 

 

Select learn

 

 

After [4] is entered, some

 

 

 

 

 

remote

 

 

zone LEDs will flash or

 

 

 

 

 

programming

 

 

stay off. The zone LEDs

 

 

 

 

 

 

 

 

represent whether that

 

 

 

 

 

 

 

 

zone is already occupied

 

 

 

 

 

 

 

 

by another remote.

 

 

 

 

 

 

 

 

** See Table A below.

 

 

 

 

 

 

 

3

 

[6] to [0]

Select remote

Select a remote

 

After you have selected

 

 

 

 

 

location

location [6], [7],

 

the remote location, that

 

 

 

 

 

(Max. 5 remotes)

[8], [9] or [0].

 

zone LED will be on.

 

 

 

 

 

 

 

4

 

Activate the

Trigger remote

Once the signal is

 

You will hear

 

 

remote by

 

transmitted to the

 

[Device X Accepted],

 

 

pressing any

 

Control Panel, that

 

where “X” is the remote

 

 

one of the

 

signal which will

 

location.

 

 

buttons.

 

be stored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE LED

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

Zone is not occupied by any remote

 

 

 

 

 

 

 

 

Flashes twice

 

This zone is occupied by another remote. Programming another

 

 

 

 

remote to this zone will overwrite the previous remote.

 

 

 

 

 

 

 

Flashes once

 

This zone is occupied by a control module* (Optional).

 

 

 

 

You can still program a remote to this zone, and it will not overwrite

 

 

 

 

the control module* you have in this zone. (Refer to page 40 Home

 

 

 

 

Automation for more information)

 

 

 

 

 

 

 

 

Flashes once,

 

This zone is occupied by a remote AND a control module*.

then twice

 

 

If you program another remote to this zone, it will overwrite the

 

 

 

 

previous remote, but not the control module*.

 

 

 

 

 

 

 

 

 

 

**Table A: Zone LED status for learning keychain/keypad remote(s).

*Please refer to learn control module on page 40.

35

Image 24
Contents Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel 905 Fax 905Email support@skylinkhome.com Home Smart Center Important Safety Instructions Declaration of Conformity EMCContent System ConfigurationOperation Disarming a triggered control panelIntroduction OverviewFCC Information Consumer Information System Configuration Introduction Accessories Control Module SW-100Control Module SW-101U UK, SW-101F French, SW-101G German Emergency Dialer AD-433SInstallation Installing the ConsoleDoor/Window Sensor WD-101 Repeater RP-434Water Sensor FS-101 Garage Door MonitorTM Sensor GS-101Trouble Shooting Programming PasswordsChanging Passwords Order to change the password, follow the procedures belowQuestions Solutions Phone Number ProgrammingControl Panel Testing Phone Numbers Home AutomationContact ID Phone number Event TriggerAccount Number Programming Zone LED DescriptionDeactivating the Digital Dialer OperationErase Control Modules Installing Door / Window Sensors Part 2 Learn signal from Control Panel to Control ModuleTesting Mounting the SensorInstalling Motion Sensor Insert BatteryPart 1 Learn signal from Control Module to Control Panel Table E Zone LED status for learning control moduleLearn Control Modules To indicate the light has been turned onAlert Mode OperationAdvanced Programming Erase SensorsMute Learn Sensors ContinueTable C System Status Arming the SystemLearn Sensors Erase Keychain / Keypad Remotes Disarming the systemDisarming a triggered control panel Disarming under DuressLearn Keychain / Keypad Remotes To enable alert zone feature, follow the instructions below PanicSystem Failure Phone Line FailureLow Battery It is recommend to enable alert zone ifSensor Failure Control PanelTo enable auto mute feature, follow the instructions below Auto MuteCommunication Receiving the Emergency CallExample To access the control panel away from home Calling in when you are away from homeSystem Armed Alarm Mode Remote Operation by TelephoneBeep / Alarm System Disarmed Alert ModeRemote Phone Operations