Multi-Link ML-100, ML-001 manual Installing Motion Sensor, Insert Battery

Page 18

INSTALLATION (ML-100A Only)

2 Single flash

1. Beep___Beep___

Beep___Beep___

............

Note:

-Try to mount the sensors as far away from the floor as possible to avoid damaging them. Mounting the sensors at a higher position will also result in better operating range.

-Do not mount the sensor to the exterior of the door / window, always mount the sensor to the interior side of the door / window to avoid being damaged or stolen by non-intended users.

Installing Motion Sensor

The motion sensor is most suitable for guarding a large area such as living room, family room, or bedroom. It can also be used to monitor a hallway or stairway.

Insert Battery

Undo the screw on the back of the motion sensor and remove the battery cover. Connect a 9V alkaline battery to the battery connector. Please note the polarity.

If you are planning to install the motion sensor outdoor, you should reduce the sensitivity by placing the jumper at location “2”.

For indoor application, if you want to reduce the sensitivity, you can change the jumper setting to

“2” as well.

 

Sensitivity

 

 

 

 

 

Jumper Location 1

High Sensitivity

 

 

 

 

 

 

Jumper Location 2

Low Sensitivity

 

 

 

 

 

Caution:

Depending on the environment, if you experience a false trigger when the motion sensor is placed outdoors, you should relocate it or even place it indoors. Wind blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the location at where the motion sensor is mounted could cause a false trigger, you should change the mounting location for such sensor.

16

HOME AUTOMATION

Part 1 Learn signal from Control Module to Control Panel

Step

Keys

 

Function

Description

Note

 

 

 

 

 

 

1

[PROG]

 

Enter Program-

Enter master

3 beeps for valid

 

[MPIN]

 

ming mode

password to

password. 1 long beep

 

 

 

 

 

programming

for invalid password.

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

2

[4]

 

 

Select learn

 

After [4] is entered, some

 

 

 

 

control module

 

zone LEDs will flash or

 

 

 

 

programming

 

stay off. The zone LEDs

 

 

 

 

 

 

represent whether that

 

 

 

 

 

 

zone is already occupied

 

 

 

 

 

 

by another control

 

 

 

 

 

 

module.**See Table E.

 

 

 

 

 

 

3

[1] to [5]

 

Select control

Select the

After you have selected

 

 

 

 

module location

location [1], [2],

the control module location,

 

 

 

 

(Max. 5 control

[3], [4], or [5].

that zone LED will be on.

 

 

 

 

modules)

 

 

 

 

 

 

 

4

Activate the

Send signal

Once the signal

You will hear

 

control module

from control

is transmitted to

[Device X Accepted],

 

by pressing its

module to

the Control Panel,

where “X” is the control

 

learn button

control panel.

that signal will be

module location.

 

once quickly.

 

stored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE LED

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

Off

 

 

Zone is not occupied by any control module

 

 

 

 

 

 

 

Flashes once

 

This zone is occupied by another control module. Programming

 

 

 

another remote to this zone will overwrite the previous control

 

 

 

module.

 

 

 

 

 

 

 

 

 

Flashes twice

 

This zone is occupied by a remote. You can still program a control

 

 

 

module to this zone, and it will not overwrite the remote you have

 

 

 

in this zone.

 

 

 

 

 

 

 

 

 

Flashes once,

 

This zone is occupied by a remote AND a control module. If you

then twice

 

program another control module to this zone, it will overwrite the

 

 

 

previous control module, but not the remote.

 

 

 

 

 

 

 

**Table E: Zone LED status for learning control module.

41

Image 18
Contents Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel 905 Fax 905Email support@skylinkhome.com Home Smart Center Important Safety Instructions Declaration of Conformity EMCOperation ContentSystem Configuration Disarming a triggered control panelIntroduction OverviewFCC Information Consumer Information System Configuration Control Module SW-101U UK, SW-101F French, SW-101G German Introduction AccessoriesControl Module SW-100 Emergency Dialer AD-433SInstallation Installing the ConsoleWater Sensor FS-101 Door/Window Sensor WD-101Repeater RP-434 Garage Door MonitorTM Sensor GS-101Changing Passwords Trouble ShootingProgramming Passwords Order to change the password, follow the procedures belowQuestions Solutions Phone Number ProgrammingControl Panel Testing Phone Numbers Home AutomationContact ID Phone number Event TriggerAccount Number Programming Zone LED DescriptionDeactivating the Digital Dialer OperationErase Control Modules Testing Installing Door / Window SensorsPart 2 Learn signal from Control Panel to Control Module Mounting the SensorPart 1 Learn signal from Control Module to Control Panel Installing Motion SensorInsert Battery Table E Zone LED status for learning control moduleLearn Control Modules To indicate the light has been turned onAdvanced Programming Alert ModeOperation Erase SensorsMute Learn Sensors ContinueTable C System Status Arming the SystemLearn Sensors Erase Keychain / Keypad Remotes Disarming the systemDisarming a triggered control panel Disarming under DuressLearn Keychain / Keypad Remotes System Failure To enable alert zone feature, follow the instructions belowPanic Phone Line FailureSensor Failure Low BatteryIt is recommend to enable alert zone if Control PanelTo enable auto mute feature, follow the instructions below Auto MuteCommunication Receiving the Emergency CallExample System Armed Alarm Mode To access the control panel away from homeCalling in when you are away from home Remote Operation by TelephoneBeep / Alarm System Disarmed Alert ModeRemote Phone Operations