Receiving the Emergency Call

If you are on the list as one of the recipients of the emergency call, you should read the following instructions carefully. You should also notify all the persons you will be calling so they know how to react when they receive the emergency call.

The control panel will call you when there are emergencies such as break-ins, smoke, fire events, or someone at home needs assistance.

1.When the phone rings at the calling location, the person who answers the phone will hear a message related to the emergency events, such as “System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be repeated several times depending on how it was programmed.

ADVANCED PROGRAMMING

Follow the procedures below to program the beep / alarm setting.

Step

Keys

Function

Description

Note

1

[PROG]

Enter Programming Enter master

3 beeps for valid password.

 

[MPIN]

mode

password to

1 long beep for invalid

 

 

 

programming mode password.

 

 

 

 

 

2

[5]

Select Beep /

 

After [5] is entered, some zone

Alarm Setting

 

LEDs will flash or stay on.

 

 

 

 

 

 

 

This indicates whether that

 

 

 

 

zone is set to beep or alarm.

 

 

 

 

 

3

Set to Beep:

Select which

Refer to the

If Alarm is set for that zone,

 

[1] to [5]

zone you would

diagram below to

that zone LED will be on. If

 

 

like to Beep or

select the appro-

Beep is set, the LED will

 

Set to Alarm:

Alarm.

priate setting.

flash. You are allowed to

 

[6] to [0].

 

 

make multiple changes before

 

 

 

terminating programming

 

 

 

 

 

 

 

 

mode.

2.After the message has been repeated for a certain number of times, the control panel will ask for a valid password, you will hear “Enter Password”.

3.Enter the 4-digit password to have access to the control panel. If a valid password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”.

4.After entering the correct password, you can follow the “Phone Command” instruc- tions to perform the required tasks, such as disarm, turn on / off devices or check the system status etc. For further information of how to control the system remotely, please refer to the next section, "Remote Operation by Telephone".

Zone 1

Sensor 1

Triggered

Enter

Password

-Arm

-Disarm

-Check status

-Control lighting etc. -Disconnect

4

[PROG] when

Terminate pro-

PROG LED will be off, and

 

finished.

gramming mode.

you will hear 3 beeps.

 

 

 

®

 

 

BEEP

ALARM

 

 

Zone 1

Button [1]

Button [6]

This row

:

Zone 2

Button [2]

Button [7]

Buttons for Beep

Zone LED : Flash

 

 

 

Zone 3

Button [3]

Button [8]

 

 

Zone 4

Button [4]

Button [9]

 

 

Zone 5

Button [5]

Button [0]

This row

:

 

 

 

Buttons for Alarm

 

 

 

Zone LED : ON

Example:

If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply press [0] at step 3.

This will change the zone 5 setting to “Alarm”.

26

31

Image 28
Contents Fax 905 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel 905Email support@skylinkhome.com Home Smart Center Important Safety Instructions Declaration of Conformity EMCContent System ConfigurationOperation Disarming a triggered control panelOverview IntroductionFCC Information Consumer Information System Configuration Introduction Accessories Control Module SW-100Control Module SW-101U UK, SW-101F French, SW-101G German Emergency Dialer AD-433SInstallation Installing the ConsoleDoor/Window Sensor WD-101 Repeater RP-434Water Sensor FS-101 Garage Door MonitorTM Sensor GS-101Trouble Shooting Programming PasswordsChanging Passwords Order to change the password, follow the procedures belowPhone Number Programming Questions SolutionsControl Panel Testing Phone Numbers Home AutomationContact ID Phone number Event TriggerAccount Number Programming Zone LED DescriptionOperation Deactivating the Digital DialerErase Control Modules Installing Door / Window Sensors Part 2 Learn signal from Control Panel to Control ModuleTesting Mounting the SensorInstalling Motion Sensor Insert BatteryPart 1 Learn signal from Control Module to Control Panel Table E Zone LED status for learning control moduleLearn Control Modules To indicate the light has been turned onAlert Mode OperationAdvanced Programming Erase SensorsLearn Sensors Continue MuteTable C Arming the System System StatusLearn Sensors Erase Keychain / Keypad Remotes Disarming the systemDisarming under Duress Disarming a triggered control panelLearn Keychain / Keypad Remotes To enable alert zone feature, follow the instructions below PanicSystem Failure Phone Line FailureLow Battery It is recommend to enable alert zone ifSensor Failure Control PanelTo enable auto mute feature, follow the instructions below Auto MuteReceiving the Emergency Call CommunicationExample To access the control panel away from home Calling in when you are away from homeSystem Armed Alarm Mode Remote Operation by TelephoneSystem Disarmed Alert Mode Beep / AlarmRemote Phone Operations