Telular SX4D Enter Periodic Self Test Time Option, Enter Dial Tone Type Selection Option

Page 34

Phonecell SX4D Programming - continued

Enter Periodic Self Test Time Option

The following key sequence is used to program periodic self test time interval:

Label: SELF TEST TIME

Data: <self-test interval>

The self-test interval is programmed in 1-minute increments from 1 to 65,535. A value of 0 disables periodic self test. If the value is not between 0 and 65,535, inclusive, it will be considered invalid. The factory default is

180.

Enter Dial Tone Type Selection Option

The following key sequence is used to select the dial tone type option:

Label: DIAL TONE TYPE

Data: <dial tone frequency>

The dial tone frequency selection option value is set to 0 to select the North American dial tone frequency pair (350 + 440 Hz); set to 1 to select European dial tone frequency (425 Hz). If the dial tone frequency selection option value is neither 0 nor 1, it is considered invalid and the Phonecell will not update or store this value; the currently stored value will remain. The factory default is 1.

Enter In-Call DTMF Signaling Option

The following key sequence is used to select if in-call DTMF signaling is enabled:

Label: IN CALL DTMF

Data: <in-call DTMF signaling enabled>

The in-call DTMF signaling value is set to 0 for disabled or 1 for enabled. If the in-call DTMF signaling value is neither 0 nor 1, it is con- sidered invalid. The factory default is 1.

Enter Mobile Equipment Personalization for SIM

The following key sequence is used to enter the MEP option:

Label: MEP: SIM

Data: <MEP Operation> * <MEP Password>

MEP operation value is set to 0 to deactivate personalization; 1 to activate personalization; 2 to disable personalization; 3 is reserved for future use. If the MEP operation value is not in the range 0 to 3, it is considered invalid.

The MEP password is a special value available only to authorized personnel. The factory default is set to 0 deactivated.

Enter Mobile Equipment Personalization for Network

The following key sequence is used to enter the MEP option:

Label: MEP: NETWORK

Data: <MEP Operation> * <MEP Password>

MEP operation value is set to 0 to deactivate personalization; 1 to activate personalization; 2 to disable personalization; 3 is reserved for future use. If the MEP operation value is not in the range 0 to 3, it is considered invalid.

The MEP password is a special value available only to authorized personnel. The factory default is set to 0 deactivated.

SX4D GSM 900 • SX4D GSM 1800

33

USER MANUAL

Image 34
Contents Phonecell SX4D GSM Phonecell SX4D GSM Tel 847-247-9400 · Fax Power SupplyIntroduction Please see Pages 7 and 8 for ImportantTable of Contents Exposure to RF Radio Frequency Energy Safety InformationTemperature Environment Safe Operation RequirementSafety Information FCC Part 15 Class B Compliance Potentially Explosive AtmospheresGSM Type Acceptance Important Notices Terms and Conditions for USE of Phonecell Products ProductIV. What this Warranty does not Cover Important NoticesGetting Started Pre-Installation ChecklistUn-Packing Your Phonecell SX4D AC Power Installation SummaryOtherwise, continue to Step Antenna Setup Optional YagiPower Connect Phonecell SX4D to AC PowerEmergency Battery Backup ReceptacleSIM Card Installation and Setup How to Install the Mini-SIM CardPress 4-digit SIM number # SIM PIN ProgrammingPress * * 04 * oldPIN * new PIN * new PIN # Enter Automatic PIN Entry Option How to Unblock a SIM PINEnter PIN For Automatic PIN Entry Determine Phonecell SX4D Location Wall-Mount Instructions Optional Wall-Mount Installation83 mm 3-1/4 inches Mounting Battery Hooks Access Door Mounting Clip Cradle tab upDialed Digits Phonecell SX4D OperationLCD Display AlphaCall-Timer Phonecell SX4D Normal Power ModePhonecell SX4D Normal Mode Phonecell SX4D OperationDialed Digits Middle Row Alpha Bottom RowIn-Use Indicator Received Signal Strength In-Use IndicatorCellular Service Indicator Cellular Service Indicator Alpha RowFront Panel Phonecell OperationPhonecell SX4D Controls Back PanelHow to End a Call How to Place a CallHow to Receive a Call Hookflash FunctionUsing Standard Supplementary Services Variable Dial Time Auto Send Delay OptionZero Dial Delay for Frequently Called Numbers Mobile Equipment Personalization MEPDelay TeleserviceCall Forwarding Unconditional Register * 31 # Call Phone Number Send Call Forwarding on No ReplyRegister # 31 # Call Phone Number Send Barring of All Outgoing Calls All Incoming Call Barring Phonecell SX4D Troubleshooting Enter Programming Mode Phonecell SX4D Programming Mode OverviewProgramming Mode Programming Mode OverviewPhonecell SX4D User-Programming Commands Phonecell SX4D ProgrammingEnter Post Receiver Off-Hook Option Phonecell SX4D Technician CommandsEnter Dial Tone After Remote Call Terminate Option Label Dtrct Data dial tone optionEnter Dial Tone Type Selection Option Enter In-Call Dtmf Signaling OptionEnter Periodic Self Test Time Option Enter Mobile Equipment Personalization for SIMEnter Mobile Equipment Personalization for Corporate Enter Mobile Equipment Personalization for Service ProviderEnter Mobile Equipment Personalization for Network Subset Enter Voicemail Retrieval Digit StringTelular Corporation