Motorola RMU2080D manual Hands Free without Accessories iVOX, Toggle Voice Prompt in User Mode

Page 36

Hands Free without Accessories (iVOX)

 

• Press the PTT button while turning ON the radio

STARTED

to enable iVOX. The icon

blinks.

• iVOX can be temporarily disabled by pressing the

 

 

PTT button.

 

 

• A short press of the PTT Button re-enables iVOX.

 

Note:

 

GETTING

• There is a short delay between the time when you

Sensitivity” on page 35.

 

 

start talking and when the radio transmits.

 

• For more information on setting VOX/iVOX

 

sensitivity, refer to “Setting VOX /iVOX

Toggle Voice Prompt in User Mode

Short press the SB1 Button while turning ON the radio to enable/disable the Voice Prompt in User Mode. (Default is set to ON).

Power Up - Tone Mode

To enable/disable power up tone mode, press SB1 and SB2 buttons simultaneously for 2-3 seconds while powering up the radio until you

English 34

hear the pre-programmed power up tone. 3 different power-up tones are available:

Power up tone and channel number announcement, or

Battery level and channel number announcements, or

Silent (Audible tones disabled)

Reset to Factory Defaults

Reset to Factory Defaults will set back all radio features to the original factory default settings. To do so, press PTT, SB2 and SB1 simultaneously while turning ON the radio until you hear a high tone chirp.

Keypad Beeps

To enable/disable Keypad Beeps, short press the SB2 button while turning ON the radio until you hear ‘chirp’ tone.

Image 36
Contents Two-Way Radios Open Source Software Legal Notices Contents Contents Troubleshooting Use and Care Frequency and Code Charts RM UHF Frequencies Chart RMU2080d UHF Default FrequenciesProduct Safety Product Safety and RF Exposure CompliancePackage Contents IntroductionUSA Canada On TTY Text Telephone FCC Licensing Information Interference InformationFCC Licensing Information Batteries Chargers Safety Information Batteries and Chargers Safety InformationBatteries and Chargers Safety Information Radio Overview Parts of the RadioRadio Lithium-Ion Li-Ion Battery Side ButtonsRMU2080d Radio Specifications Battery Features About the Li-Ion BatteryBattery Recycling and Disposal BatteryInstalling the Lithium-Ion Li-Ion Battery Removing the Lithium-Ion Li-Ion BatteryHolster ChargerBattery Life Information Li-Ion Battery Life with Tx Power 2 WattsBattery Meter RM Series Battery MeterBars Charging the Battery Charging with the Drop-in Tray Single Unit Charger SUCTo charge only the battery at on Motorola Authorized BatteriesDrop-in Tray Charger LED Indicators Status LED Indicator CommentsBattery Estimated Charging Time Standard Battery High Capacity BatteryEstimated Charging Time Radio Multi-Unit Charger LED Indicators Radio Overview Adjusting Volume Getting StartedStarted Turning Radio ON/OFFSelecting a Channel Talking and MonitoringReceiving a Call Signal Strength Indicator and Channel Busy Indicators Talk RangeIndustrial Multi-Level Getting Started Radio LED Indicators Radio Status LED IndicationWith Compatible VOX Accessories HANDS-FREE USE/VOXHands Free without Accessories iVOX Toggle Voice Prompt in User ModePower Up Tone Mode Reset to Factory DefaultsSetting VOX /iVOX Sensitivity Keypad Lock/UnlockMenu Options Getting Started Programming Features Advanced Configuration ModeEntering Advanced Configuration Mode Programming RX Reception Frequencies Programming RX Reception Codes CTCSS/DPLProgramming Scramble Programming Maximum Number ChannelsProgramming Call Tones Programming Microphone Gain Level Accessory Gain Level Programming MicrophoneOther Programming Features ScanProgramming Scan List Programming Weather ChannelEditing Channel Alias Name ProgrammingNuisance Channel Delete Customer Programming Software CPSTime-Out Timer Power SelectCall Tones ScrambleReverse Burst Weather ChannelPublic Service Band Frequencies MHz National Weather Service. When Noaa Weather AlertCloning Radios Cloning with a Multi Unit Charger MUCFurther details on how to clone radios are CPS and Cloning Cables Optional Accessory CPS CableOperating Instructions What To Do If Cloning Fails Cloning using the Customer Programming Software CPS Troubleshooting SymptomRange. Check for clear line of sight to improve transmission Troubleshooting VOX feature might be set to OFF USE and Care Code Frequency and Code Charts Frequency and ChartsFrequency and Code Charts Frequency and Code Charts RMU2080Dd UHF Default Frequencies Chart Ctcss and PL/DPL Codes PL/DPL Codes 111 Frequency and Code Charts 190 Inverted DPL 200 210 191 201 211 192 202 Frequency and Code Warranty for Motorola LimitedUnited States CanadaAltered Products. Products or Accessories with ExclusionsHOW to Obtain Warranty Service or Other INFORMATION? SoftwareWHO is COVERED? Software Copyright NoticePatent Notice Export LAW AssurancesAccessories Audio AccessoriesBattery CablesCarry Accessories Software ApplicationsAccessories Battery Save Buttons ResetDisplay Display BacklightChannel AliasingChannels Cloning Mode CPS ManagerLock FrequenciesIVOX, enable DisableDisplay Bandwidth RangeLEDs Enabled Disabled Low BatteryDisplay Keypad Lock AlertDisplay Microphone MonitorNuisance Ch DeletePower Select Power Up TextReset to DefaultsTimer Display ScanMultiple Scan ListVOX, enable VOXSilent Mode Power UpDisplay Channel Busy Lock OutPriority Scan Pre-DefinedVoice Prompt Programmable Buttons Chart Icons Chart Signal Strength Vox/IVoxPage 68012009073