Motorola RMU2080D manual Radio

Page 27

Charging a Radio and Battery using a Multi Unit-Charger - MUC (Optional Accessory)

Charger Power Receptacle

Charging Contacts

Charging Pocket

Charging Indicator

The Multi-Unit Charger (MUC) allows drop-in charging of up to 6 radios or batteries. Batteries can be charged with the radios or removed and placed in the MUC separately. Each of the 6 charging pockets can hold a radio (with or without the Holster) or battery, but not both.

1.

Place the Multi-Unit Charger on a flat surface.

 

 

2.

Insert the power cord plug into the MUC’s dual

 

 

pin connector at the bottom of the MUC.

 

3.

Plug the power cord into an AC outlet.

RADIO

4.

pocket with the radio or battery facing away

Turn the radio OFF.

 

5.

Insert the radio or battery into the charging

 

 

from the contacts.

OVERVIEW

Note:

 

This Multi-Unit Charger clones up to 2 radios (2

 

 

Source radios and 2 Target radios). Refer to

 

 

“Cloning with a Multi Unit Charger (MUC)” on

 

 

page 51 for more information.

 

More information on the Multi-Unit Charger’s

 

 

operation is available in the Instruction Sheets

 

 

provided with the MUC. For more information on

 

 

the parts and their part numbers, refer to Chapter

 

 

 

 

“Accessories” on page 76.

 

25 English

Image 27
Contents Two-Way Radios Open Source Software Legal Notices Contents Contents RM UHF Frequencies Chart RMU2080d UHF Default Frequencies Troubleshooting Use and Care Frequency and Code ChartsProduct Safety and RF Exposure Compliance Product SafetyIntroduction Package ContentsUSA Canada On TTY Text Telephone Interference Information FCC Licensing InformationFCC Licensing Information Batteries and Chargers Safety Information Batteries Chargers Safety InformationBatteries and Chargers Safety Information Parts of the Radio Radio OverviewRadio Side Buttons Lithium-Ion Li-Ion BatteryRMU2080d Radio Specifications About the Li-Ion Battery Battery FeaturesBattery Battery Recycling and DisposalRemoving the Lithium-Ion Li-Ion Battery Installing the Lithium-Ion Li-Ion BatteryCharger HolsterLi-Ion Battery Life with Tx Power 2 Watts Battery Life InformationBattery Meter RM Series Battery MeterBars Charging with the Drop-in Tray Single Unit Charger SUC Charging the BatteryMotorola Authorized Batteries To charge only the battery at onStatus LED Indicator Comments Drop-in Tray Charger LED IndicatorsBattery Estimated Charging Time Standard Battery High Capacity BatteryEstimated Charging Time Radio Multi-Unit Charger LED Indicators Radio Overview Turning Radio ON/OFF Adjusting VolumeGetting Started StartedSelecting a Channel Talking and MonitoringReceiving a Call Signal Strength Indicator and Channel Busy Indicators Talk RangeIndustrial Multi-Level Getting Started Radio Status LED Indication Radio LED IndicatorsHANDS-FREE USE/VOX With Compatible VOX AccessoriesReset to Factory Defaults Hands Free without Accessories iVOXToggle Voice Prompt in User Mode Power Up Tone ModeSetting VOX /iVOX Sensitivity Keypad Lock/UnlockMenu Options Getting Started Programming Features Advanced Configuration ModeEntering Advanced Configuration Mode Programming RX Reception Codes CTCSS/DPL Programming RX Reception FrequenciesProgramming Scramble Programming Maximum Number ChannelsProgramming Call Tones Programming Microphone Gain Level Programming Microphone Accessory Gain LevelScan Other Programming FeaturesProgramming Weather Channel Programming Scan ListProgramming Editing Channel Alias NameCustomer Programming Software CPS Nuisance Channel DeleteScramble Time-Out TimerPower Select Call TonesWeather Channel Reverse BurstPublic Service Band Frequencies MHz Noaa Weather Alert National Weather Service. WhenCloning with a Multi Unit Charger MUC Cloning RadiosFurther details on how to clone radios are CPS Cable CPS and Cloning Cables Optional AccessoryOperating Instructions What To Do If Cloning Fails Cloning using the Customer Programming Software CPS Symptom TroubleshootingRange. Check for clear line of sight to improve transmission Troubleshooting VOX feature might be set to OFF USE and Care Frequency and Charts Code Frequency and Code ChartsFrequency and Code Charts Frequency and Code Charts RMU2080Dd UHF Default Frequencies Chart Ctcss and PL/DPL Codes PL/DPL Codes 111 Frequency and Code Charts 190 Inverted DPL 200 210 191 201 211 192 202 Frequency and Code Canada Warranty forMotorola Limited United StatesExclusions Altered Products. Products or Accessories withSoftware Copyright Notice HOW to Obtain Warranty Service or Other INFORMATION?Software WHO is COVERED?Export LAW Assurances Patent NoticeCables AccessoriesAudio Accessories BatterySoftware Applications Carry AccessoriesAccessories Display Backlight Battery SaveButtons Reset DisplayChannel AliasingChannels Frequencies Cloning ModeCPS Manager LockRange IVOX, enableDisable Display BandwidthAlert LEDs EnabledDisabled Low Battery Display Keypad LockDelete Display MicrophoneMonitor Nuisance ChDefaults Power SelectPower Up Text Reset toScan List TimerDisplay Scan MultipleVOX VOX, enableLock Out Silent ModePower Up Display Channel BusyPriority Scan Pre-DefinedVoice Prompt Programmable Buttons Chart Icons Chart Strength Vox/IVox SignalPage 68012009073